STUDIES OF MIGRATION TIME REPRODUCIBILITY OF CAPILLARY ELECTROPHORETIC PROTEIN SEPARATIONS

被引:52
作者
STREGE, MA
LAGU, AL
机构
[1] Lilly Research Laboratories, A Division of Eli Lilly and Company, Indianapolis
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1993年 / 16卷 / 01期
关键词
D O I
10.1080/10826079308020896
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Studies of the migration time reproducibility of trypsinogen were performed using a capillary electrophoresis system designed for high resolution protein separations, where analyte adsorption and electroosmotic flow were minimized through the use of poly-(acrylamide)-derivatized capillaries coated with 3-(dimethyldodecylammonio)-propanesulfonate, a zwitterionic surfactant. The results of this investigation suggested that oxidation-induced pH drifts occurring at the electrodes had a significant impact upon protein migration. Acceptable migration time reproducibility (<2% RSD for a series of nine injections) was found to be dependent upon buffer replenishment at both electrodes prior to each injection. These results indicate that instruments which can provide preinjection buffer replenishment may be necessary for the qualitative or quantitative analysis of proteins using poly-(acrylamide) coated capillaries.
引用
收藏
页码:51 / 68
页数:18
相关论文
共 54 条
[1]  
ANDREWS AT, 1986, ELECTRPPOO, pCH1
[2]   FACTORS THAT INFLUENCE MOBILITY, RESOLUTION, AND SELECTIVITY IN CAPILLARY ZONE ELECTROPHORESIS .3. THE ROLE OF THE BUFFERS ANION [J].
ATAMNA, IZ ;
METRAL, CJ ;
MUSCHIK, GM ;
ISSAQ, HJ .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (16) :3201-3210
[3]   FACTORS THAT INFLUENCE MOBILITY, RESOLUTION AND SELECTIVITY IN CAPILLARY ZONE ELECTROPHORESIS .2. THE ROLE OF THE BUFFERS CATION [J].
ATAMNA, IZ ;
METRAL, CJ ;
MUSCHIK, GM ;
ISSAQ, HJ .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (13) :2517-2527
[4]  
ATKINS PW, 1986, PHYSICAL CHEM, P658
[5]  
BRATTSTEN I, 1955, ARK KEMI, V8, P205
[6]   CAPILLARY ZONE ELECTROPHORETIC SEPARATIONS OF PROTEINS IN POLYETHYLENE GLYCOL-MODIFIED CAPILLARIES [J].
BRUIN, GJM ;
CHANG, JP ;
KUHLMAN, RH ;
ZEGERS, K ;
KRAAK, JC ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1989, 471 :429-436
[7]   ELECTROPHORETIC SEPARATIONS OF PROTEINS IN CAPILLARIES WITH HYDROLYTICALLY STABLE SURFACE-STRUCTURES [J].
COBB, KA ;
DOLNIK, V ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1990, 62 (22) :2478-2483
[8]   INFLUENCE OF THERMAL VARIATION OF DIFFUSION-COEFFICIENT ON NONEQUILIBRIUM PLATE HEIGHT IN CAPILLARY ZONE ELECTROPHORESIS [J].
DAVIS, JM .
JOURNAL OF CHROMATOGRAPHY, 1990, 517 :521-547
[9]  
DULLFER T, 1990, CHROMATOGRAPHIA, V30, P675
[10]   EQUATIONS FOR CALCULATION OF CHROMATOGRAPHIC FIGURES OF MERIT FOR IDEAL AND SKEWED PEAKS [J].
FOLEY, JP ;
DORSEY, JG .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :730-737