STUDIES OF MIGRATION TIME REPRODUCIBILITY OF CAPILLARY ELECTROPHORETIC PROTEIN SEPARATIONS

被引:52
作者
STREGE, MA
LAGU, AL
机构
[1] Lilly Research Laboratories, A Division of Eli Lilly and Company, Indianapolis
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1993年 / 16卷 / 01期
关键词
D O I
10.1080/10826079308020896
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Studies of the migration time reproducibility of trypsinogen were performed using a capillary electrophoresis system designed for high resolution protein separations, where analyte adsorption and electroosmotic flow were minimized through the use of poly-(acrylamide)-derivatized capillaries coated with 3-(dimethyldodecylammonio)-propanesulfonate, a zwitterionic surfactant. The results of this investigation suggested that oxidation-induced pH drifts occurring at the electrodes had a significant impact upon protein migration. Acceptable migration time reproducibility (<2% RSD for a series of nine injections) was found to be dependent upon buffer replenishment at both electrodes prior to each injection. These results indicate that instruments which can provide preinjection buffer replenishment may be necessary for the qualitative or quantitative analysis of proteins using poly-(acrylamide) coated capillaries.
引用
收藏
页码:51 / 68
页数:18
相关论文
共 54 条
[41]   DISPERSION EFFECTS IN CAPILLARY ZONE ELECTROPHORESIS [J].
ROBERTS, GO ;
RHODES, PH ;
SNYDER, RS .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :35-67
[42]   CHARACTERIZATION AND AUTOMATION OF SAMPLE INTRODUCTION METHODS FOR CAPILLARY ZONE ELECTROPHORESIS [J].
ROSE, DJ ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1988, 60 (07) :642-648
[43]   CONSTANT (OPTIMUM) POWER ELECTROPHORESIS [J].
SCHAFFER, HE ;
JOHNSON, FM .
ANALYTICAL BIOCHEMISTRY, 1973, 51 (02) :577-583
[44]   PERFORMANCE OF AN AUTOMATED INJECTION AND REPLENISHMENT SYSTEM FOR CAPILLARY ELECTROPHORESIS [J].
SCHWARTZ, HE ;
MELERA, M ;
BROWNLEE, RG .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :129-139
[45]  
SNYDER LR, 1979, INTRO MODERN LIQUID, pCH5
[46]   SEPARATION OF DNA RESTRICTION FRAGMENTS BY CAPILLARY ELECTROPHORESIS USING COATED FUSED-SILICA CAPILLARIES [J].
STREGE, M ;
LAGU, A .
ANALYTICAL CHEMISTRY, 1991, 63 (13) :1233-1236
[48]   CHARACTERIZATION OF PROTEIN BEHAVIOR IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS USING A NOVEL CAPILLARY SYSTEM [J].
SWEDBERG, SA .
ANALYTICAL BIOCHEMISTRY, 1990, 185 (01) :51-56
[49]   ELECTROKINETIC CHROMATOGRAPHY WITH MICELLAR SOLUTION AND OPEN-TUBULAR CAPILLARY [J].
TERABE, S ;
OTSUKA, K ;
ANDO, T .
ANALYTICAL CHEMISTRY, 1985, 57 (04) :834-841
[50]   CAPILLARY ELECTROPHORETIC SEPARATIONS OF PROTEINS USING NONIONIC SURFACTANT COATINGS [J].
TOWNS, JK ;
REGNIER, FE .
ANALYTICAL CHEMISTRY, 1991, 63 (11) :1126-1132