INFLUENCE OF SHOES AND HEEL STRIKE ON THE LOADING OF THE HIP-JOINT

被引:67
作者
BERGMANN, G
KNIGGENDORF, H
GRAICHEN, F
ROHLMANN, A
机构
[1] Oskar-Helene-Heim, Biomechanics Laboratory, Orthopaedic Hospital, D-1000 Berlin 33
关键词
D O I
10.1016/0021-9290(94)00129-R
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The forces and moments acting at the hip joint influence the long-term stability of the fixation of endoprostheses and the course of coxarthrosis. These loads may depend on the kind of footwear and the walking or running style. These factors were investigated in a patient with instrumented hip implants. He wore different sports shoes, normal leather shoes, hiking boots and clogs and walked barefoot with soft, normal and hard heel strikes. The loads were lowest while walking and jogging without shoes. All shoes increased the joint force and the bending moment at the implant slightly, but the torsional moment rose by up to 50%. No relation was found between the different type of shoes and the load increase, only shoes with very hard soles were clearly disadvantageous. Soft heels, soles or insoles did not offer advantages. Gait stability seems to play the most important role in increasing the joint loading and should be the criterion for the choice of footwear. Smooth gait patterns with soft heel strikes are the only means to reduce joint loading during slow jogging.
引用
收藏
页码:817 / 827
页数:11
相关论文
共 43 条
[1]   HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[2]   EVALUATION OF ISCHIAL WEIGHT-BEARING ORTHOSES, BASED ON IN-VIVO HIP-JOINT FORCE MEASUREMENTS [J].
BERGMANN, G ;
DASILVA, MC ;
NEFF, G ;
ROHLMANN, A ;
GRAICHEN, F .
CLINICAL BIOMECHANICS, 1994, 9 (04) :225-234
[3]   MULTICHANNEL STRAIN-GAUGE TELEMETRY FOR ORTHOPEDIC IMPLANTS [J].
BERGMANN, G ;
GRAICHEN, F ;
SIRAKY, J ;
JENDRZYNSKI, H ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1988, 21 (02) :169-176
[4]  
Bergmann G, 1990, IMPLANTABLE TELEMETR, P35
[5]   A MODEL OF LOWER-EXTREMITY MUSCULAR ANATOMY [J].
BRAND, RA ;
CROWNINSHIELD, RD ;
WITTSTOCK, CE ;
PEDERSEN, DR ;
CLARK, CR ;
VANKRIEKEN, FM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (04) :304-310
[6]  
CROWINSHIELD RD, 1978, CLIN ORTHOP RELAT R, P140
[7]   BIOMECHANICAL INVESTIGATION OF HUMAN HIP [J].
CROWNINSHIELD, RD ;
JOHNSTON, RC ;
ANDREWS, JG ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1978, 11 (1-2) :75-85
[8]   TELEMETRIC FORCE MEASUREMENTS ACROSS THE HIP AFTER TOTAL ARTHROPLASTY [J].
DAVY, DT ;
KOTZAR, GM ;
BROWN, RH ;
HEIPLE, KG ;
GOLDBERG, VM ;
HEIPLE, KG ;
BERILLA, J ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (01) :45-50
[9]  
Frederick E.C., 1984, SPORT SHOES PLAYING, P1
[10]   ANALYSIS OF PROTECTING EFFECT OF SHOCK ABSORBING SHOES FOR PATIENTS WITH HIP AND KNEE ALLOARTHROPLASTY [J].
GEBAUER, D ;
CZIUK, N .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1988, 126 (05) :582-588