TRIANGLE PROGRAMMED COULOMETRIC FLOW TITRATION WITH POTENTIOMETRIC AND OPTICAL-DETECTION

被引:10
作者
FEHER, Z [1 ]
NAGY, G [1 ]
SLEZSAK, I [1 ]
TOTH, K [1 ]
PUNGOR, E [1 ]
机构
[1] TECH UNIV BUDAPEST,INST GEN & ANALYT CHEM,H-1521 BUDAPEST,HUNGARY
关键词
COULOMETRY; FLOW SYSTEM; POTENTIOMETRY; TITRIMETRY; UV VISIBLE SPECTROPHOTOMETRY; NICOTINIC ACID; PHARMACEUTICALS; TRIANGLE PROGRAMMED COULOMETRIC FLOW TITRATION;
D O I
10.1016/0003-2670(93)80198-T
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of a flow-through titration technique, the so-called triangle programmed coulometric titration, is presented for acid-base titrations using potentiometric and photometric detection. A flow-through capillary glass electrode-saturated calomel electrode pair was employed for potentiometric detection, and an indicator mixture and a light-emitting diode-phototransistor system was used for photometric detection. In photometric detection the precision of the end-point location was enhanced by the addition of a suitable mixture of Methyl Red and m-Cresol Purple acid-base colour indicators. The suitability of the technique was demonstrated for different acid-base titrations. As an example, the determination of the drug content of a nicotinic acid-containing experimental pharmaceutical preparation is described.
引用
收藏
页码:521 / 530
页数:10
相关论文
共 19 条
[11]   NOVEL TITRATION TECHNIQUE FOR ANALYSIS OF STREAMED SAMPLES - TRIANGLE-PROGRAMMED TITRATION TECHNIQUE .3. TITRATIONS WITH ELECTRICALLY GENERATED BROMINE [J].
NAGY, G ;
FEHER, Z ;
TOTH, K ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1978, 100 (SEP) :181-191
[12]   NOVEL TITRATION TECHNIQUE FOR ANALYSIS OF STREAMED SAMPLES - TRIANGLE-PROGRAMMED TITRATION TECHNIQUE .2. ARGENTIMETRIC TITRATIONS [J].
NAGY, G ;
FEHER, Z ;
TOTH, K ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1977, 91 (02) :97-106
[13]   NOVEL TITRATION TECHNIQUE FOR ANALYSIS OF STREAMED SAMPLES - TRIANGLE-PROGRAMMED TITRATION TECHNIQUE .1. GENERAL CONSIDERATIONS [J].
NAGY, G ;
FEHER, Z ;
TOTH, K ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1977, 91 (02) :87-96
[14]  
PUNGOR E, 1983, CRC CR REV ANAL CHEM, V14, P175
[15]   AN IMPROVED FLOW THROUGH PHOTOTRANSDUCER [J].
SLY, TJ ;
BETTERIDGE, D ;
WIBBERLEY, D ;
PORTER, DG .
JOURNAL OF AUTOMATIC CHEMISTRY, 1982, 4 (04) :186-189
[16]   SOLID-STATE PHOTOMETRIC DETECTORS FOR FLOW-INJECTION ANALYSIS [J].
TROJANOWICZ, M ;
WORSFOLD, PJ ;
CLINCH, JR .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1988, 7 (08) :301-305
[17]   SIMULTANEOUS FLOW-INJECTION DETERMINATION OF ALUMINUM AND ZINC USING LED PHOTOMETRIC DETECTION [J].
TROJANOWICZ, M ;
SZPUNARLOBINSKA, J .
ANALYTICA CHIMICA ACTA, 1990, 230 (01) :125-130
[18]   SPECTROPHOTOMETRIC FIELD-MONITOR FOR WATER-QUALITY PARAMETERS - THE DETERMINATION OF PHOSPHATE [J].
WORSFOLD, PJ ;
CLINCH, JR ;
CASEY, H .
ANALYTICA CHIMICA ACTA, 1987, 197 :43-50
[19]  
1986, PHARMACOPOEIA HUNGAR