USEFULNESS OF REPEAT CORONARY ANGIOGRAPHY 24 HOURS AFTER SUCCESSFUL BALLOON ANGIOPLASTY TO EVALUATE EARLY LUMINAL DETERIORATION AND FACILITATE QUANTITATIVE-ANALYSIS

被引:24
作者
FOLEY, DP
DECKERS, J
VANDENBOS, AA
HEYNDRICKX, GR
LAARMAN, GJ
SURYAPRANATA, H
ZIJLSTRA, F
SERRUYS, PW
机构
[1] ERASMUS UNIV ROTTERDAM,CTR THORAX,EE2332,POB 1738,3000 DR ROTTERDAM,NETHERLANDS
[2] ONZE LIEVE VROUW HOSP,AMSTERDAM,NETHERLANDS
[3] ST IGNATIUS ZIEKENHUIS,BREDA,NETHERLANDS
[4] HOSP WEEZENLANDEN,ZWOLLE,NETHERLANDS
[5] ONZE LIEVE VROUWE KLIN,AALST,BELGIUM
关键词
D O I
10.1016/0002-9149(93)90176-D
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Because of the unavoidable occurrence of vessel disruption after successful coronary balloon angioplasty, the reliability of quantitative angiographic analysis in that setting has been questioned. For this reason and the suggested occurrence of delayed elastic recoil, repeat angiography at 24 hours has been advocated in clinical interventional trials. In this study, these issues are confronted by performing comprehensive quantitative analysis (Cardiovascular Angiographic Analysis System) of coronary angiograms, acquired in multiple identical projections immediately after and 24 hours after angioplasty, in 102 patients with 110 successfully dilated lesions. Vasomotion was controlled by intracoronary nitrate before angiography and all patients were fully anticoagulated (activated partial thromboplastin time 85 to 120 seconds) for >24 hours. Paired Student's t tests applied to angiographic measurements revealed that there was no significant deterioration in minimal luminal diameter or cross-sectional area from immediately after angioplasty to 24 hours later. It can thus be inferred that there is no phenomenon of delayed elastic recoil, at least during this time period. Measurement accuracy and precision of the Cardiovascular Angiographic Analysis System from the postangioplasty angiogram are highly acceptable, at <0.01 and +/- 0.20 mm, respectively. Therefore, it is concluded that routine repeat 24-hour angiography is not indicated after successful angioplasty. A highly significant increase (p <0.001) in reference diameter (+0.11 +/- 0.18 mm) was responsible for the apparent increase in percent diameter stenosis (2.4 +/- 7%), a finding that demonstrates the potential for error by selective application of percent diameter stenosis measurements alone. Preferential use of absolute luminal measurements is thus strongly recommended for clinical trials with angiographic monitoring.
引用
收藏
页码:1341 / 1347
页数:7
相关论文
共 28 条
[1]   CHANGE IN DIAMETER OF CORONARY-ARTERY SEGMENTS ADJACENT TO STENOSIS AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - FAILURE OF PERCENT DIAMETER STENOSIS MEASUREMENT TO REFLECT MORPHOLOGIC CHANGES INDUCED BY BALLOON DILATION [J].
BEATT, KJ ;
LUIJTEN, HE ;
DEFEYTER, PJ ;
VANDENBRAND, M ;
REIBER, JHC ;
SERRUYS, PW ;
TENKATEN, HJ ;
VANES, GA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (02) :315-323
[2]   RESTENOSIS AFTER CORONARY ANGIOPLASTY - NEW STANDARDS FOR CLINICAL-STUDIES [J].
BEATT, KJ ;
SERRUYS, PW ;
HUGENHOLTZ, PG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (02) :491-498
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   THE ANGLE OF INCIDENCE OF THE ULTRASONIC BEAM - A CRITICAL FACTOR FOR THE IMAGE QUALITY IN INTRAVASCULAR ULTRASONOGRAPHY [J].
DIMARIO, C ;
MADRETSMA, S ;
LINKER, D ;
THE, SHK ;
BOM, N ;
SERRUYS, PW ;
GUSSENHOVEN, EJ ;
ROELANDT, JRTC .
AMERICAN HEART JOURNAL, 1993, 125 (02) :442-448
[5]   CALIBRATION USING ANGIOGRAPHIC CATHETERS AS SCALING DEVICES - IMPORTANCE OF FILMING THE CATHETERS NOT FILLED WITH CONTRAST-MEDIUM [J].
DIMARIO, C ;
HERMANS, WRM ;
RENSING, BJ ;
SERRUYS, PW .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (16) :1377-1378
[6]   ARTERIAL INJURY AND THE ENIGMA OF CORONARY RESTENOSIS [J].
ELLIS, SG ;
MULLER, DWM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) :275-277
[7]   INVIVO VALIDATION OF ONLINE AND OFF-LINE GEOMETRIC CORONARY MEASUREMENTS USING INSERTION OF STENOSIS PHANTOMS IN PORCINE CORONARY-ARTERIES [J].
HAASE, J ;
DIMARIO, C ;
SLAGER, CJ ;
VANDERGIESSEN, WJ ;
DENBOER, A ;
DEFEYTER, PJ ;
REIBER, JHC ;
VERDOUW, PD ;
SERRUYS, PW .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 27 (01) :16-27
[8]   INFLUENCE OF BALLOON SIZE AND STENOSIS MORPHOLOGY ON IMMEDIATE AND DELAYED ELASTIC RECOIL AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
HANET, C ;
WIJNS, W ;
MICHEL, X ;
SCHROEDER, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (02) :506-511
[9]   USEFULNESS OF QUANTITATIVE AND QUALITATIVE ANGIOGRAPHIC LESION MORPHOLOGY, AND CLINICAL CHARACTERISTICS IN PREDICTING MAJOR ADVERSE CARDIAC EVENTS DURING AND AFTER NATIVE CORONARY BALLOON ANGIOPLASTY [J].
HERMANS, WRM ;
FOLEY, DP ;
RENSING, BJ ;
RUTSCH, W ;
HEYNDRICKX, GR ;
DANCHIN, N ;
MAST, G ;
HANET, C ;
LABLANCHE, JM ;
RAFFLENBEUL, W ;
UEBIS, R ;
BALCON, R ;
DEFEYTER, PJ ;
SERRUYS, PW .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (01) :14-20
[10]   THERAPEUTIC DISSECTION AFTER SUCCESSFUL CORONARY BALLOON ANGIOPLASTY - NO INFLUENCE ON RESTENOSIS OR ON CLINICAL OUTCOME IN 693 PATIENTS [J].
HERMANS, WRM ;
RENSING, BJ ;
FOLEY, DP ;
DECKERS, JW ;
RUTSCH, W ;
EMANUELSSON, H ;
DANCHIN, N ;
WIJNS, W ;
CHAPPUIS, F ;
SERRUYS, PW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (04) :767-780