QUANTITATIVE PRECISION OF AN AUTOMATED IMAGE CYTOMETRIC SYSTEM FOR THE MEASUREMENT OF DNA CONTENT AND DISTRIBUTION IN CELLS LABELED WITH FLUORESCENT NUCLEIC-ACID STAINS

被引:17
作者
POULIN, N
HARRISON, A
PALCIC, B
机构
[1] B.C. Cancer Research Centre Cancer Imaging, Vancouver, British Columbia
来源
CYTOMETRY | 1994年 / 16卷 / 03期
关键词
FLUORESCENCE; CYTOPHOTOMETRY; IMAGE CYTOMETRY; DAPI; GLARE; CCD;
D O I
10.1002/cyto.990160306
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automated image cytometric system is described for the measurement of DNA content and distribution in cells stained with fluorescent DNA binding or intercalating compounds. The quantitative precision of integrated optical intensity (IOI) measurements using this system was estimated to be 2.0%, based on the coefficient of variation (cv) of the IOI of DNA check beads. Using peripheral blood lymphocytes stained with 4'-6-diamidino-2-phenylindole (DAPI), the cv of IOI was found to be 3.5%. Slide to slide variability of the IOI for peripheral blood lymphocytes (cv over 10 slides of the mean IOI) was found to be 2%. The most important sources of error in these measurements were glare, illumination instability, image calibration instability, and staining non-uniformity. These errors were investigated and minimized. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:227 / 235
页数:9
相关论文
共 20 条
[1]   5-PARAMETER FLUORESCENCE IMAGING - WOUND-HEALING OF LIVING SWISS 3T3 CELLS [J].
DEBIASIO, R ;
BRIGHT, GR ;
ERNST, LA ;
WAGGONER, AS ;
TAYLOR, DL .
JOURNAL OF CELL BIOLOGY, 1987, 105 (04) :1613-1622
[2]   OPTICAL ERRORS IN SCANNING STAGE ABSORBANCE CYTOPHOTOMETRY .1. PROCEDURES FOR CORRECTING APPARENT INTEGRATED ABSORBANCE VALUES FOR DISTRIBUTIONAL, GLARE, AND DIFFRACTION ERRORS [J].
DUIJNDAM, WAL ;
SMEULDERS, AWM ;
VANDUIJN, P ;
VERWEIJ, AC .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1980, 28 (05) :388-394
[3]   IMAGING CYTOMETRY BY MULTIPARAMETER FLUORESCENCE [J].
GALBRAITH, W ;
WAGNER, MCE ;
CHAO, J ;
ABAZA, M ;
ERNST, LA ;
NEDERLOF, MA ;
HARTSOCK, RJ ;
TAYLOR, DL ;
WAGGONER, AS .
CYTOMETRY, 1991, 12 (07) :579-596
[4]   PROBLEM OF SIZE DEPENDENCE IN FLUORESCENCE DNA CYTOMETRY [J].
HAMADA, S ;
FUJITA, S .
CYTOMETRY, 1989, 10 (04) :394-401
[5]   SEGMENTATION OF STAINED BLOOD-CELL IMAGES MEASURED AT HIGH SCANNING DENSITY WITH HIGH MAGNIFICATION AND HIGH NUMERICAL APERTURE OPTICS [J].
HARMS, H ;
AUS, HM ;
HAUCKE, M ;
GUNZER, U .
CYTOMETRY, 1986, 7 (06) :522-531
[6]  
HEDLEY DW, 1993, CYTOMETRY, V14, P471
[7]  
JAGGI B, 1991, SPIE CAMERA INPUT SC, V1448, P89
[8]  
JERICEVIC Z, 1989, METHOD CELL BIOL, V30, P47
[9]  
KOMITOWSKI D, 1990, CANCER, V65, P2725, DOI 10.1002/1097-0142(19900615)65:12<2725::AID-CNCR2820651221>3.0.CO
[10]  
2-U