MICROSEQUENCE ANALYSIS OF PEPTIDES AND PROTEINS .9. AN IMPROVED, COMPACT, AUTOMATED INSTRUMENT

被引:14
作者
CALAYCAY, J [1 ]
RUSNAK, M [1 ]
SHIVELY, JE [1 ]
机构
[1] CITY HOPE NATL MED CTR,BIOMED INSTRUMENTAT SERV,DUARTE,CA 91010
关键词
D O I
10.1016/0003-2697(91)90177-U
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe the construction of an improved, compact protein sequencer with a vertical flow path and continuous flow reactor (CFR). Unique features include a hexagonal valve for six fluid inputs to the CFR, which connects vertically to a transfer valve that allows sample, reagent, and solvent input to a conversion flask (CF). The simplified CF contains only two inputs at the top, one for sample, reagent, and solvent input, and the other a vent. The CF drains from the bottom, connecting to a switching valve which allows either delivery to waste or to an on-line HPLC for the analysis of phenylthiohydantoin amino acid derivatives. Approximately 90% of the sample is analyzed by use of a sonic flow detector. The overall vertical flow path of the sequencer is about 16 cm. The size of the instrument (25 w × 38 h × 44 d cm) is smaller than that of commercially available sequencers or HPLC systems. The performance of the instrument includes reduced background peaks and high-sensitivity sequence analysis at the 5-10 pmol level. The simplified sequencer is more economical and portable than conventional sequencers. © 1991.
引用
收藏
页码:23 / 31
页数:9
相关论文
共 19 条
[11]  
REIMANN F, 1986, METHODS PROTEIN SEQU, P409
[12]  
Shively J E, 1981, Methods Enzymol, V79, P31
[13]   MICROSEQUENCE ANALYSIS OF PEPTIDES AND PROTEINS .6. A CONTINUOUS-FLOW REACTOR FOR SAMPLE CONCENTRATION AND SEQUENCE-ANALYSIS [J].
SHIVELY, JE ;
MILLER, P ;
RONK, M .
ANALYTICAL BIOCHEMISTRY, 1987, 163 (02) :517-529
[14]   POLY-QUARTERNARY AMINES PREVENT PEPTIDE LOSS FROM SEQUENATORS [J].
TARR, GE ;
BEECHER, JF ;
BELL, M ;
MCKEAN, DJ .
ANALYTICAL BIOCHEMISTRY, 1978, 84 (02) :622-627
[15]   SENSITIZATION OF EDMAN AMINO-ACID DERIVATIVES USING THE FLUORESCENT REAGENT, 4-AMINOFLUORESCEIN [J].
TSUGITA, A ;
KAMO, M ;
JONE, CS ;
SHIKAMA, N .
JOURNAL OF BIOCHEMISTRY, 1989, 106 (01) :60-65
[16]   AMINO-ACID SEQUENCE STUDIES ON 10 RIBOSOMAL-PROTEINS OF ESCHERICHIA-COLI WITH AN IMPROVED SEQUENATOR EQUIPPED WITH AN AUTOMATIC CONVERSION DEVICE [J].
WITTMANNLIEBOLD, B .
HOPPE-SEYLERS ZEITSCHRIFT FUR PHYSIOLOGISCHE CHEMIE, 1973, 354 (10-1) :1415-1431
[17]   DEVICE COUPLED TO A MODIFIED SEQUENATOR FOR AUTOMATED CONVERSION OF ANILINOTHIAZOLINONES INTO PTH AMINO-ACIDS [J].
WITTMANNLIEBOLD, B ;
GRAFFUNDER, H ;
KOHLS, H .
ANALYTICAL BIOCHEMISTRY, 1976, 75 (02) :621-633
[18]   MICROSEQUENCE ANALYSIS OF PEPTIDES AND PROTEINS .8. IMPROVED ELECTROBLOTTING OF PROTEINS ONTO MEMBRANES AND DERIVATIZED GLASS-FIBER SHEETS [J].
XU, QY ;
SHIVELY, JE .
ANALYTICAL BIOCHEMISTRY, 1988, 170 (01) :19-30
[19]   RAPID ANALYSIS OF AMINO-ACID PHENYLTHIOHYDANTOINS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ZIMMERMAN, CL ;
APPELLA, E ;
PISANO, JJ .
ANALYTICAL BIOCHEMISTRY, 1977, 77 (02) :569-573