Next-generation drug-eluting stents in coronary artery disease: focus on everolimus-eluting stent (Xience V-(R))

被引:86
作者
Sheiban, Imad [1 ]
Villata, Gianluca [1 ]
Bollati, Mario [1 ]
Sillano, Dario [1 ]
Lotrionte, Marzia [2 ]
Biondi-Zoccai, Giuseppe [1 ]
机构
[1] Univ Turin, Div Cardiol, Intervent Cardiol, Turin, Italy
[2] Catholic Univ, Inst Cardiol, Rome, Italy
关键词
coronary artery disease; everolimus; percutaneous transluminal coronary angioplasty; stent;
D O I
10.2147/vhrm.2008.04.01.31
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Percutaneous coronary revascularization has been a mainstay in the management of coronary artery disease since its introduction in the late 1970s. Bare-metal stents and, more recently, first-generation drug-eluting stents (DES), such as sirolimus-eluting (Cypher((R))) and paclitaxel-eluting stents (Taxus((R))), have further improved results of percutaneous coronary intervention (PCI) by improving early results and reducing the risk of restenosis. There is currently debate on the safety of these first-generation DES, given the potential for late stent thrombosis, especially after discontinuation of dual antiplatelet therapy. There are well known caveats on the performance of their respective metallic stent platforms, delivery, and dilation systems, and polymer coatings. Second-generation DES, such as zotarolimus-eluting (Endeavor((R))) and everolimus-eluting stents (Xience V-(R)), have recently become available in the USA and/or Europe. The Xience V stent holds the promise of superior anti-restenotic efficacy as well as long-term safety. In addition, this stent is based on the Multi-link platform and delivery system. Recently available data already suggest the superiority of the Xience V stent in comparison to the Taxus stent in terms of prevention of restenosis, without significant untoward events. Nonetheless, the number of patients studied and the follow-up duration are still too limited to enable definitive conclusions. Only indirect meta-analyses can be used to date to compare the Xience V with the Cypher. This systematic review tries to provide a concise and critical appraisal of the data in support of the Xience V everolimus-eluting stent.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 66 条
[11]   Direct and indirect comparison meta-analysis demonstrates the superiority of sirolimus- versus paclitaxel-eluting stents across 5854 patients [J].
Biondi-Zoccai, Giuseppe G. L. ;
Lotrionte, Marzia ;
Abbate, Antonio ;
Valgimigli, Marco ;
Testa, Luca ;
Burzotta, Francesco ;
Crea, Filippo ;
Agostoni, Pierfrancesco .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 114 (01) :104-105
[12]   A systematic review and meta-analysis on the hazards of discontinuing or not adhering to aspirin among 50 279 patients at risk for coronary artery disease [J].
Biondi-Zoccai, Giuseppe G. L. ;
Lotrionte, Marzia ;
Agostoni, Pierfrancesco ;
Abbate, Antonio ;
Fusaro, Massimiliano ;
Burzotta, Francesco ;
Testa, Luca ;
Sheiban, Imad ;
Sangiorgi, Giuseppe .
EUROPEAN HEART JOURNAL, 2006, 27 (22) :2667-2674
[13]  
Biondi-Zoccai Giuseppe G L, 2004, Ital Heart J, V5, P486
[14]  
Biondi-Zoccai Giuseppe G L, 2003, Ital Heart J, V4, P271
[15]   Adjusted indirect comparison of intracoronary drug-eluting stents: evidence from a metaanalysis of randomized bare-metal-stent-controlled trials [J].
Biondi-Zoccai, GL ;
Agostoni, P ;
Abbate, A ;
Testa, L ;
Burzotta, F ;
Lotrionte, M ;
Crea, F ;
Biasucci, LM ;
Vetrovec, GW ;
Colombo, A .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 100 (01) :119-123
[16]   Optimal medical therapy with or without PCI for stable coronary disease [J].
Boden, William E. ;
O'Rourke, Robert A. ;
Teo, Koon K. ;
Hartigan, Pamela M. ;
Maron, David J. ;
Kostuk, William J. ;
Knudtson, Merril ;
Dada, Marcin ;
Casperson, Paul ;
Harris, Crystal L. ;
Chaitman, Bernard R. ;
Shaw, Leslee ;
Gosselin, Gilbert ;
Nawaz, Shah ;
Title, Lawrence M. ;
Gau, Gerald ;
Blaustein, Alvin S. ;
Booth, David C. ;
Bates, Eric R. ;
Spertus, John A. ;
Berman, Daniel S. ;
Mancini, G. B. John ;
Weintraub, William S. ;
Boden, W. ;
O'Rourke, R. ;
Teo, K. ;
Hartigan, P. ;
Weintraub, W. ;
Maron, D. ;
Mancini, J. ;
Weintraub, W. ;
Boden, W. ;
O'Rourke, R. ;
Teo, K. ;
Hartigan, P. ;
Knudtson, M. ;
Maron, D. ;
Bates, E. ;
Blaustein, A. ;
Booth, D. ;
Carere, R. ;
Ellis, S. ;
Gosselin, G. ;
Gau, G. ;
Jacobs, A. ;
King, S., III ;
Kostuk, W. ;
Harris, C. ;
Spertus, J. ;
Peduzzi, P. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (15) :1503-1516
[17]   Manual thrombus-aspiration improves myocardial reperfusion - The randomized evaluation of the effect of mechanical reduction of distal embolization by thrombus-aspiration in primary and rescue angioplasty (REMEDIA) trial [J].
Burzotta, F ;
Trani, C ;
Romagnoli, E ;
Mazzari, MA ;
Rebuzzi, AG ;
De Vita, M ;
Garramone, B ;
Giannico, F ;
Niccoli, G ;
Biondi-Zoccai, GGL ;
Schiavoni, G ;
Mongiardo, R ;
Crea, F .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (02) :371-376
[18]   Experimental efficacy of an everolimus eluting cobalt chromium stent [J].
Carter, AJ ;
Brodeur, A ;
Collingwood, R ;
Ross, S ;
Gibson, L ;
Wang, CA ;
Haller, S ;
Coleman, L ;
Virmani, R .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (01) :97-103
[19]   TOR of the cell cycle: Are there important implications for diabetics in the era of the drug-eluting stent? [J].
Carter, AJ .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (02) :233-236
[20]   Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions [J].
Colombo, A ;
Drzewiecki, J ;
Banning, A ;
Grube, E ;
Hauptmann, K ;
Silber, S ;
Dudek, D ;
Fort, S ;
Schiele, F ;
Zmudka, K ;
Guagliumi, G ;
Russell, ME .
CIRCULATION, 2003, 108 (07) :788-794