NEW DESIGN FOR FOURIER-TRANSFORM INFRARED VIBRATIONAL CIRCULAR-DICHROISM SPECTROMETERS

被引:12
作者
CHEN, GC
POLAVARAPU, PL
WEIBEL, S
机构
[1] VANDERBILT UNIV,DEPT CHEM,NASHVILLE,TN 37235
[2] ATI INSTRUMENTS NA,MADISON,WI 53717
关键词
VIBRATIONAL CIRCULAR DICHROISM; CYCLODEXTRINS; PHASE CORRECTION;
D O I
10.1366/0003702944027499
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Fourier transform infrared (FT-IR) spectrometers are commonly designed with small-area detectors and tight focusing mirrors. Vibrational circular dichroism (VCD) measurements made with such FT-IR instruments contain polarization artifacts, and VCD measurements on both enantiomers (or one enantiomer and racemic mixture) are required in order to reduce these artifacts. This restriction limits the VCD measurements to only those samples for which both enantiomers (or one enantiomer and racemic mixture) are available. Recently a modified design was reported in the literature where the mirrors between sample and detector were replaced with a BaF2 lens, and a larger-area detector was substituted for the smaller-area counterpart. These modifications successfully alleviated some of the artifact problems. This design, however, is not suitable for polarizing interferometers, where polarizations exiting the interferometer are to be preserved to a high degree of purity. In addition, it is not clear whether the throughput enhancement advantage realized with a larger-area detector completely offsets the disadvantage from increased noise with detector area. Furthermore, BaF, lenses reduce the broad range routinely available on an FT-IR instrument. Here we report a new design that replaces all the mirrors at the exit port of the interferometer with two KBr lenses and retains the full spectral range (4000-400 cm(-1)) of mid-infrared FT-IR spectrometers. VCD measurements obtained with small-(1 x 1 mm) and large-(4 x 4 mm) area detectors are found to have similar signal quality.
引用
收藏
页码:1218 / 1223
页数:6
相关论文
共 23 条
[1]   INFRARED CIRCULAR-DICHROISM AND LINEAR DICHROISM SPECTROPHOTOMETER [J].
CHABAY, I ;
HOLZWARTH, G .
APPLIED OPTICS, 1975, 14 (02) :454-459
[2]   DESIGN AND PERFORMANCE OF AN OPTIMIZED DISPERSIVE INFRARED DICHROGRAPH [J].
DIEM, M ;
ROBERTS, GM ;
LEE, O ;
BARLOW, A .
APPLIED SPECTROSCOPY, 1988, 42 (01) :20-27
[4]   STEREOCHEMICAL ASPECTS OF VIBRATIONAL OPTICAL-ACTIVITY [J].
FREEDMAN, TB ;
NAFIE, LA .
TOPICS IN STEREOCHEMISTRY, 1987, 17 :113-206
[5]  
GRIFFITHS PR, 1988, FOURIER TRANSFORM IN
[6]   INFRARED CIRCULAR-DICHROISM OF CARBON-HYDROGEN AND CARBON-DEUTERIUM STRETCHING MODES - OBSERVATIONS [J].
HOLZWART.G ;
HSU, EC ;
MOSHER, HS ;
FAULKNER, TR ;
MOSCOWIT.A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1974, 96 (01) :251-252
[7]   POLARIZATION-MODULATION FT-IR REFLECTION SPECTROSCOPY USING A POLARIZING MICHELSON INTERFEROMETER [J].
ISHIDA, H ;
ISHINO, Y ;
BUIJS, H ;
TRIPP, C ;
DIGNAM, MJ .
APPLIED SPECTROSCOPY, 1987, 41 (08) :1288-1294
[8]   VIBRATIONAL CIRCULAR-DICHROISM [J].
KEIDERLING, TA .
APPLIED SPECTROSCOPY REVIEWS, 1981, 17 (02) :189-226
[9]  
KEIDERLING TA, 1990, PRACTICAL FOURIER TR, P204
[10]   A SOLUTION TO THE ARTIFACT PROBLEM IN FOURIER-TRANSFORM VIBRATIONAL CIRCULAR-DICHROISM [J].
MALON, P ;
KEIDERLING, TA .
APPLIED SPECTROSCOPY, 1988, 42 (01) :32-38