NEW AEROSOL DELIVERY SYSTEM FOR NEONATAL VENTILATOR CIRCUITS

被引:29
作者
EVERARD, ML [1 ]
STAMMERS, J [1 ]
HARDY, JG [1 ]
MILNER, AD [1 ]
机构
[1] QUEENS MED CTR, DEPT MED PHYS, NOTTINGHAM NG7 2UH, ENGLAND
来源
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION | 1992年 / 67卷 / 07期
关键词
D O I
10.1136/adc.67.7_Spec_No.826
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
There is mounting evidence that a variety of drugs delivered as aerosols are likely to be of benefit in neonatal units. To avoid many of the problems associated with the use of jet nebulisers in ventilator circuits, a chamber was designed to be used in conjunction with a metered dose inhaler (MDI). The dimensions (4 cmX11 cm) were chosen in an attempt to maximise drug delivery. In vitro studies were subsequently performed in order to determine the optimum operating conditions. Sodium cromoglycate delivered via this system was collected on a filter placed between the tip of an endotracheal tube and a model lung. The dose delivered was determined by means of an ultraviolet spectrophotometric assay. Using a Draeger Babylog 8000 ventilator it was found that drug delivery as maximised by actuating the device just before the inspiratory cycle when the chamber was placed adjacent to the endotracheal tube and by using a long (one second) inspiratory time. Under these conditions 1.5-2% of the original dose was deposited upon the filter at tidal volumes of 11-22 ml. When considered in terms of body weight this is many times the equivalent dose delivered to adults from an MDI. Effective drug delivery to the filter was confirmed using a radiolabelled aerosol. Radiolabelled studies delivering aerosol to the lungs of intubated rabbits demonstrated that deposition aerosol was distributed uniformly between lobes when corrected for the weight of each lobe. In conclusion, the device appears likely to deliver significant, reproducible quantities of drug to the lower respiratory tract while being simple to use.
引用
收藏
页码:826 / 830
页数:5
相关论文
共 16 条
  • [1] AEROSOL DELIVERY DEVICES FOR THE ANESTHESIA CIRCUIT
    BUSH, GL
    [J]. ANESTHESIOLOGY, 1986, 65 (02) : 240 - 240
  • [2] EVALUATION OF NEBULIZERS FOR USE IN NEONATAL VENTILATOR CIRCUITS
    CAMERON, D
    CLAY, M
    SILVERMAN, M
    [J]. CRITICAL CARE MEDICINE, 1990, 18 (08) : 866 - 870
  • [3] AEROSOL DELIVERY IN NEONATAL VENTILATOR CIRCUITS - A RABBIT LUNG MODEL
    CAMERON, D
    ARNOT, R
    CLAY, M
    SILVERMAN, M
    [J]. PEDIATRIC PULMONOLOGY, 1991, 10 (03) : 208 - 213
  • [4] DELIVERY EFFICIENCY OF METERED DOSE AEROSOLS GIVEN VIA ENDOTRACHEAL-TUBES
    CROGAN, SJ
    BISHOP, MJ
    [J]. ANESTHESIOLOGY, 1989, 70 (06) : 1008 - 1010
  • [5] A CONTROLLED TRIAL OF DEXAMETHASONE IN PRETERM INFANTS AT HIGH-RISK FOR BRONCHOPULMONARY DYSPLASIA
    CUMMINGS, JJ
    DEUGENIO, DB
    GROSS, SJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1989, 320 (23) : 1505 - 1510
  • [6] DAHLBACK M, 1989, J AEROSOL MED, V2, P339
  • [7] DRUG DELIVERY FROM HOLDING CHAMBERS WITH ATTACHED FACEMASK
    EVERARD, ML
    CLARK, AR
    MILNER, AD
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1992, 67 (05) : 580 - 585
  • [8] PRESSURIZED AEROSOL VERSUS JET AEROSOL DELIVERY TO MECHANICALLY VENTILATED PATIENTS - COMPARISON OF DOSE TO THE LUNGS
    FULLER, HD
    DOLOVICH, MB
    POSMITUCK, G
    PACK, WW
    NEWHOUSE, MT
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1990, 141 (02): : 440 - 444
  • [9] METERED DOSE INHALERS FOR BRONCHODILATOR DELIVERY IN INTUBATED, MECHANICALLY VENTILATED PATIENTS
    GAY, PC
    PATEL, HG
    NELSON, SB
    GILLES, B
    HUBMAYR, RD
    [J]. CHEST, 1991, 99 (01) : 66 - 71
  • [10] GOMEZDELRIO M, 1986, PEDIATR PULM, V2, P287