摘要
Nine different 25% cyanobiphenyl-substituted polysiloxane (CBP) stationary phases were evaluated for use in gas and supercritical fluid chromatography. They were easily coated and cross-linked on fused silica capillaries to produce highly efficient columns. For a 200 mum i.d. column, an efficiency of as high as 5,100 plates m-1 was obtained. For most of the new phases, the upper temperature limit was 300-degrees-C. A comparative study of the chromatographic behaviors of the cyanobiphenyl and commercial reference phases was made. Some of the cyanobiphenyl stationary phases showed polarities higher than those for carbowax 20M or 50% cyanopropyl. All six positional isomers of dodecylxylene and the five isomers of four-ring polycyclic aromatic hydrocarbons were baseline resolved on GC capillary columns with certain of the cyanobiphenyl phases, demonstrating higher selectivity over SE-54 or Carbowax 20M phases. In SFC, a cyanobiphenyl column provided better separation of a standard coal tar sample than columns with biphenyl or cyanopropyl phases. The retention behavior of fatty acid methyl esters and a mixture of polar solutes was investigated on the cyanobiphenyl and reference phases. With respect to certain solute pairs, the selectivities of the new stationary phases were found to increase with temperature. The new cyanobiphenyl phases were found to be useful for GC and SFC separations of various classes of complex mixtures including essential oils, explosives, and polycyclic aromatic hydrocarbons.
引用
收藏
页码:529 / 540
页数:12
相关论文
共 24 条
[1]  
[Anonymous], 1970, J CHROMATOGR SCI, DOI DOI 10.1093/CHROMSCI/8.12.685
[2]  
BLUM W, 1988, J HIGH RES CHROMATOG, V11, P148
[3]   PREPARATION OF GLASS-CAPILLARY COLUMNS COATED WITH IMMOBILIZED OV-240-OH (33-PERCENT CYANOPROPYL SUBSTITUTED, OH-TERMINATED) - AN APPROACH TO IMPROVE THE INERTNESS AND THERMAL-STABILITY OF CYANOALKYL POLYSILOXANE COATINGS [J].
BLUM, W .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (06) :350-354
[4]   CHARACTERIZATION OF SELECTIVITY OF STATIONARY PHASES FROM PARTIAL MOLAR FREE-ENERGIES OF SOLUTION OF STANDARDS [J].
GOLOVNYA, RV ;
MISHARINA, TA .
CHROMATOGRAPHIA, 1977, 10 (11) :658-660
[5]  
GOLOVNYA RV, 1980, HIGH RESOL CHROMATOG, V3, P51
[6]   PREPARATION AND SEPARATION PROPERTIES OF OPEN TUBULAR COLUMNS WITH IMMOBILIZED CARBOWAX 20M FOR LC [J].
JANAK, K ;
HORKA, M ;
KREJCI, M .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1991, 3 (02) :115-120
[7]   4-(METHYLSULFONYL)PHENYL-CONTAINING POLYSILOXANE STATIONARY PHASE FOR CAPILLARY COLUMN GAS-CHROMATOGRAPHY [J].
JUVANCZ, Z ;
SCHIRMER, MM ;
JOHNSON, DF ;
MARKIDES, KE ;
BRADSHAW, JS ;
LEE, ML .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1991, 3 (04) :349-353
[8]  
KOSKI IJ, 1991, THESIS B YOUNG U PRO
[9]  
KOSTROMIN SG, 1991, VYSOKOMOLEKYLYARNYE, V35, P115
[10]  
LEE ML, 1984, OPEN TUBULAR COLUMN, P74