EFFECT OF TEMPERATURE ON FINGER ARTERY PRESSURE EVALUATED BY VOLUME CLAMP TECHNIQUE

被引:34
作者
TANAKA, H
THULESIUS, O
机构
[1] Department of Clinical Physiology, Faculty of Health Sciences, University Hospital, Linkoping
来源
CLINICAL PHYSIOLOGY | 1993年 / 13卷 / 05期
关键词
FINAPRES; DIGITAL ARTERY PRESSURE; COLD INDUCED VASOCONSTRICTION; RAYNAUD SYNDROME; NONINVASIVE PRESSURE MEASUREMENT;
D O I
10.1111/j.1475-097X.1993.tb00469.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We examined the effect of temperature on digital arterial blood pressure obtained by continuous beat-to-beat non-invasive monitoring with a volume-clamp technique (Finapres). In 10 normal volunteers and 13 patients with symptoms of vasospasm, digital pressure and brachial artery pressure (cuff method) was simultaneously recorded in control conditions at room temperature, during body cooling, finger heating, and truncal heating. In the control condition digital systolic blood pressure was significantly higher (16.1 +/- 14.2 mmHg) than brachial systolic pressure. The augmentation of digital systolic pressure correlated inversely with finger tip temperature. Diastolic and mean arterial pressure did not differ significantly between the two methods. Body cooling augmented the systolic finger-arm gradient while truncal heating and finger heating had the opposite effect. Finger heating reduced systolic augmentation without changing the mean and diastolic blood pressure. Similar changes were also observed in the patients with vasospasm except in one case with a pronounced Raynaud syndrome where digital blood pressure was lower than brachial artery pressure. We conclude that augmentation of finger systolic pressure seems to be dependent on local vasoconstriction of A/V shunts and that finger heating may be a useful procedure to improve the reliability of Finapres readings.
引用
收藏
页码:535 / 545
页数:11
相关论文
共 19 条
[1]   COMPARATIVE ACCURACIES OF A FINGER BLOOD-PRESSURE MONITOR AND AN OSCILLOMETRIC BLOOD-PRESSURE MONITOR [J].
EPSTEIN, RH ;
HUFFNAGLE, S ;
BARTKOWSKI, RR .
JOURNAL OF CLINICAL MONITORING, 1991, 7 (02) :161-167
[2]   NONINVASIVE VS INVASIVE BEAT-TO-BEAT MONITORING OF BLOOD-PRESSURE [J].
GABRIEL, A ;
LINDBLAD, LE ;
ANGLERYD, C .
CLINICAL PHYSIOLOGY, 1992, 12 (02) :229-235
[3]   THE ACCURACY OF FINAPRES NONINVASIVE MEAN ARTERIAL-PRESSURE MEASUREMENTS IN ANESTHETIZED PATIENTS [J].
GIBBS, NM ;
LARACH, DR ;
DERR, JA .
ANESTHESIOLOGY, 1991, 74 (04) :647-652
[4]   ON THE RELIABILITY OF THE PENAZ CUFF DURING SYSTEMIC AND LOCAL FINGERTIP VASODILATATION AT REST AND IN EXERCISE [J].
HILDEBRANDT, W ;
SCHUTZE, H ;
STEGEMANN, J .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1991, 62 (03) :175-179
[5]  
Imholz B P, 1991, Clin Auton Res, V1, P43, DOI 10.1007/BF01826057
[6]   CONTINUOUS NON-INVASIVE BLOOD-PRESSURE MONITORING - RELIABILITY OF FINAPRES DEVICE DURING THE VALSALVA MANEUVER [J].
IMHOLZ, BPM ;
VANMONTFRANS, GA ;
SETTELS, JJ ;
VANDERHOEVEN, GMA ;
KAREMAKER, JM ;
WIELING, W .
CARDIOVASCULAR RESEARCH, 1988, 22 (06) :390-397
[7]   NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT DURING ORTHOSTATIC STRESS COMPARED TO INTRAARTERIAL PRESSURE [J].
IMHOLZ, BPM ;
SETTELS, JJ ;
VANDERMEIRACKER, AH ;
WESSELING, KH ;
WIELING, W .
CARDIOVASCULAR RESEARCH, 1990, 24 (03) :214-221
[8]  
KURKI T, 1987, J CLIN MONITOR, V3, P3
[9]   PULSE-WAVE PROPAGATION [J].
LI, JKJ ;
MELBIN, J ;
RIFFLE, RA ;
NOORDERGRAAF, A .
CIRCULATION RESEARCH, 1981, 49 (02) :442-452