LUNG AS A FILTER FOR MICROBUBBLES

被引:272
作者
BUTLER, BD [1 ]
HILLS, BA [1 ]
机构
[1] UNIV TEXAS,MED BRANCH,INST BIOPHYS & MARINE BIOMED,GALVESTON,TX 77550
关键词
D O I
10.1152/jappl.1979.47.3.537
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A new ultrasonic Doppler device has been used noninvasively over the femoral artery of anesthetized dogs to prove that it can detect carefully calibrated microbubbles of 14-189 μm diam when these are infused directly into the aorta. The same evaluated technique has then been employed to detect any bubbles escaping into the arterial system when gas was infused into the venous system either as microbubbles or as a bolus. Results from 18 dogs showed that, under normal conditions, the lungs are a superb filter for bubbles and that any cutoff diameter is less than 22 μm. However, bubbles escaped entrapment when the lungs were severely overloaded with gas (20 ml) or were pretreated with a pulmonary vasodilator (aminophylline). The dog preparation and arterial Doppler device appear to be ideal for future studies to determine what other factors might compromise the capability of the lungs to filter microbubbles. Physiological parameters showed dramatic changes when bubbles were detected as escaping into the arterial system by comparison with their effect when retained within the lungs. Changes in respiration profile indicated that they may offer a useful index of the degree of venous embolization and, hence, a warning of impending overload leading to arterial embolization.
引用
收藏
页码:537 / 543
页数:7
相关论文
共 28 条
  • [11] FRYER DI, 1969, SUBATMOSPHERIC DECOM
  • [12] GARDETTE BC, 1977, MED SUB HYP, V64, P419
  • [13] SIZE OF THE LARGEST ARTERIO-VENOUS VESSELS IN VARIOUS ORGANS
    GORDON, DB
    FLASHER, J
    DRURY, DR
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1953, 173 (02): : 275 - 281
  • [14] GRULKE DC, 1973, BRIT J EXP PATHOL, V54, P684
  • [15] Bubble formation in animals II. Gas nuclei and their distribution in blood and tissues
    Harvey, EN
    Whiteley, AH
    McElroy, WD
    Pease, DC
    Barnes, DK
    [J]. JOURNAL OF CELLULAR AND COMPARATIVE PHYSIOLOGY, 1944, 24 (01): : 23 - 34
  • [16] HEINEMANN HO, 1969, PHYSIOL REV, V49, P1
  • [17] EVALUATION OF ULTRASONIC BUBBLE DETECTORS INVITRO USING CALIBRATED MICROBUBBLES AT SELECTED VELOCITIES
    HILLS, BA
    GRULKE, DC
    [J]. ULTRASONICS, 1975, 13 (04) : 181 - 184
  • [18] HILLS BA, 1978, UNDERSEA BIOMED RES, V5, P58
  • [19] AIR BUBBLES IN WATER
    LIEBERMANN, L
    [J]. JOURNAL OF APPLIED PHYSICS, 1957, 28 (02) : 205 - 211
  • [20] MASUREL G, 1978, UNDERSEA BIOMED RES, V5, P29