QUANTITATIVE EXERCISE TL-201 ROTATIONAL TOMOGRAPHY FOR EVALUATION OF PATIENTS WITH PRIOR MYOCARDIAL-INFARCTION

被引:19
作者
CHOURAQUI, P
MADDAHI, J
OSTRZEGA, E
VANTRAIN, K
CHARUZI, Y
PRIGENT, F
BERMAN, DS
机构
[1] CEDARS SINAI MED CTR, DEPT MED,DIV CARDIOL,8700 BEVERLY BLVD,POB 48750, LOS ANGELES, CA 90048 USA
[2] CEDARS SINAI MED CTR, DEPT NUCL MED, LOS ANGELES, CA 90048 USA
[3] UNIV CALIF LOS ANGELES, SCH MED, DEPT MED, LOS ANGELES, CA 90024 USA
关键词
D O I
10.1016/0002-9149(90)90579-P
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The utility of stress-redistribution thallium-201 myocardial perfusion single-photon emission computed tomography (SPECT) in patients with a prior single myocardial infarction was studied in 66 patients who were tested by both SPECT and coronary angiography. SPECT was quantified by comparing the patients' circumferential count profiles to a previously established normal data base and by plotting the results onto a polar coordinate map that localized defects to the 3 major coronary artery territories. The pattern of reversibility of the quantitatively detected defects was assessed by consensus visual analysis. SPECT thallium-201 detected myocardial infarction in 62 of 66 patients (sensitivity = 94%). Sixty-five percent of the infarct zones showed some reversibility at 4-hour imaging which corresponded with angiographic evidence of flow to the infarct zones in 95.5% of cases. Late (18 to 24 hours) imaging, done in 26 patients, showed complete or partial reversibility of 29% of infarct zone segments which were nonreversible on 4-hour images. To improve specificity for detection of disease in coronary arteries supplying the non-infarct territories, new quantitative criteria were developed that took into consideration contiguity of defects with the infarct zone. Accuracy for detection of patients with multivessel coronary disease by quantitative thallium-201 SPECT was 86%, which was significantly higher than those of the clinical response to exercise (48%), the exercise electrocardiographic response (56%) or their combination (65%). The following can be concluded: thallium-201 SPECT is accurate for detection of prior myocardial infarction; defect reversibility is common in the infarct zones and late imaging is superior to 4-hour imaging in this regard; thallium-201 is more accurate than clinical and/or electrocardiographic responses to exercise for detection of disease in coronary arteries supplying the noninfarcted regions. © 1990.
引用
收藏
页码:151 / 157
页数:7
相关论文
共 30 条
  • [21] VALUE AND LIMITATIONS OF SEGMENTAL ANALYSIS OF STRESS THALLIUM MYOCARDIAL IMAGING FOR LOCALIZATION OF CORONARY-ARTERY DISEASE
    RIGO, P
    BAILEY, IK
    GRIFFITH, LSC
    PITT, B
    BUROW, RD
    WAGNER, HN
    BECKER, LC
    [J]. CIRCULATION, 1980, 61 (05) : 973 - 981
  • [22] MYOCARDIAL IMAGING WITH TL-201 AT REST AND DURING EXERCISE - COMPARISON WITH CORONARY ARTERIOGRAPHY AND RESTING AND STRESS ELECTROCARDIOGRAPHY
    RITCHIE, JL
    TROBAUGH, GB
    HAMILTON, GW
    GOULD, KL
    NARAHARA, KA
    MURRAY, JA
    WILLIAMS, DL
    [J]. CIRCULATION, 1977, 56 (01) : 66 - 71
  • [23] TRANSAXIAL TOMOGRAPHY WITH TL-201 FOR DETECTING REMOTE MYOCARDIAL-INFARCTION - COMPARISON WITH PLANAR IMAGING
    RITCHIE, JL
    WILLIAMS, DL
    HARP, G
    STRATTON, JL
    CALDWELL, JH
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1982, 50 (06) : 1236 - 1241
  • [24] USE OF TL-201 REDISTRIBUTION SCINTIGRAPHY IN THE PREOPERATIVE DIFFERENTIATION OF REVERSIBLE AND NON-REVERSIBLE MYOCARDIAL ASYNERGY
    ROZANSKI, A
    BERMAN, DS
    GRAY, R
    LEVY, R
    RAYMOND, M
    MADDAHI, J
    PANTELEO, N
    WAXMAN, AD
    SWAN, HJC
    MATLOFF, J
    [J]. CIRCULATION, 1981, 64 (05) : 936 - 944
  • [25] SOBEL BE, 1976, CIRCULATION, V53, P146
  • [26] RELATION OF GLOBAL AND REGIONAL LEFT-VENTRICULAR FUNCTION TO TOMOGRAPHIC TL-201 MYOCARDIAL PERFUSION IN PATIENTS WITH PRIOR MYOCARDIAL-INFARCTION
    STRATTON, JR
    SPECK, SM
    CALDWELL, JH
    MARTIN, GV
    CERQUEIRA, M
    MAYNARD, C
    DAVIS, KB
    KENNEDY, JW
    RITCHIE, JL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (01) : 71 - 77
  • [27] STRESS TL-201 TRANSAXIAL EMISSION COMPUTED-TOMOGRAPHY - QUANTITATIVE VERSUS QUALITATIVE-ANALYSIS FOR EVALUATION OF CORONARY-ARTERY DISEASE
    TAMAKI, N
    YONEKURA, Y
    MUKAI, T
    KODAMA, S
    KADOTA, K
    KAMBARA, H
    KAWAI, C
    TORIZUKA, K
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (06) : 1213 - 1221
  • [28] GATED CARDIAC BLOOD POOL IMAGING AND TL-201 MYOCARDIAL SCINTIGRAPHY FOR DETECTION OF REMOTE MYOCARDIAL-INFARCTION
    TIEFENBRUNN, AJ
    BIELLO, DR
    GELTMAN, EM
    SOBEL, BE
    SIEGEL, BA
    ROBERTS, R
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1981, 47 (01) : 1 - 6
  • [29] TURNER DA, 1978, J NUCL MED, V19, P249
  • [30] DETECTION OF RESIDUAL JEOPARDIZED MYOCARDIUM 3 WEEKS AFTER MYOCARDIAL-INFARCTION BY EXERCISE TESTING WITH TL-201 MYOCARDIAL SCINTIGRAPHY
    TURNER, JD
    SCHWARTZ, KM
    LOGIC, JR
    SHEFFIELD, LT
    KANSAL, S
    ROITMAN, DI
    MANTLE, JA
    RUSSELL, RO
    RACKLEY, CE
    ROGERS, WJ
    [J]. CIRCULATION, 1980, 61 (04) : 729 - 737