SCANNER-INDUCED VARIABILITY AND QUALITY ASSURANCE IN LONGITUDINAL DUAL-ENERGY X-RAY ABSORPTIOMETRY MEASUREMENTS

被引:40
作者
SIEVANEN, H
OJA, P
VUORI, I
机构
[1] The UKK Institute, FIN-33501, Tampere
关键词
DXA; RELIABILITY; SCANNER-INDUCED VARIABILITY; LONGITUDINAL STUDIES;
D O I
10.1118/1.597278
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Characteristics of typical malfunctions and scanner-induced variability observed in dual-energy x-ray absorptiometry (DXA), and their potential effects on longitudinal reliability of DXA were evaluated. According to extensive, cumulative quality assurance (QA) data obtained from two successive x-ray sources during a 3-yr period, the scanner-induced variability may derive from long-term drift (~0.5%/year), short-term drift (~0.2%-2.2%/day), inhomogeneity of the x-ray beam intensity over the tabletop (~1%), and changes in internal filtration (~0.5%). The absolute magnitudes of these effects may be considerable with respect to expected small changes in bone characteristics observed in intervention studies. Furthermore, these effects may not be discriminated from each other. Therefore it may not be possible to correct their cumulative effect using long-term QA data only. The observed drifts are fortunately negligible with respect to the precision adequate for clinical decision making. In contrast, the evaluation of these multiform scanner-induced variability is warranted in longitudinal intervention studies using DXA. It is emphasized that this study was performed with a single DXA system, and the results should be considered accordingly; nevertheless, it is believed that the issues raised would apply to other systems too, at least in the sense of stringent QA. In this respect, single daily phantom measurement appeared to be occasionally ineffective, whereas a remeasurement of the phantom after subject measurements significantly improved the effectiveness of QA. Altogether, the QA procedures, which consider both the short-term and long-term variability as well as the spatial variability over the tabletop, may provide a more effective method to detect silently degrading scanner performance and evaluate its effects on the subject measurements. High-quality operator performance is, however, a prerequisite for proper QA in any setting. © 1994, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1795 / 1805
页数:11
相关论文
共 32 条
[1]  
ARAI H, 1990, IMAGE TECHNOL INFORM, V22, P1
[2]   DUAL ENERGY X-RAY ABSORPTIOMETRY - THE EFFECTS OF BEAM HARDENING ON BONE-DENSITY MEASUREMENTS [J].
BLAKE, GM ;
MCKEENEY, DB ;
CHHAYA, SC ;
RYAN, PJ ;
FOGELMAN, I .
MEDICAL PHYSICS, 1992, 19 (02) :459-465
[3]   COMPARISON OF 4 DUAL ENERGY IMAGE DECOMPOSITION METHODS [J].
CHUANG, KS ;
HUANG, HK .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (04) :455-466
[4]  
FISCHER M, 1993, EUR J NUCL MED, V20, P434
[5]   SOME EFFECTS OF BASIC MULTICELLULAR UNIT-BASED REMODELING ON PHOTON-ABSORPTIOMETRY OF TRABECULAR BONE [J].
FROST, HM .
BONE AND MINERAL, 1989, 7 (01) :47-65
[6]   SYSTEMATIC BIAS IN BASIS MATERIAL DECOMPOSITION APPLIED TO QUANTITATIVE DUAL-ENERGY X-RAY-IMAGING [J].
GINGOLD, EL ;
HASEGAWA, BH .
MEDICAL PHYSICS, 1992, 19 (01) :25-33
[7]   QUALITY ASSURANCE FOR BONE DENSITOMETRY RESEARCH STUDIES - CONCEPT AND IMPACT [J].
GLUER, CC ;
FAULKNER, KG ;
ESTILO, MJ ;
ENGELKE, K ;
ROSIN, J ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1993, 3 (05) :227-235
[8]   EVALUATION OF A NEW SET OF CALIBRATION STANDARDS FOR THE MEASUREMENT OF FAT-CONTENT VIA DPA AND DXA [J].
GOODSITT, MM .
MEDICAL PHYSICS, 1992, 19 (01) :35-44
[9]   CURRENT STATUS OF PHYSICAL MEASUREMENTS OF THE SKELETON [J].
GREENFIELD, MA .
MEDICAL PHYSICS, 1992, 19 (06) :1349-1357
[10]   INFLUENCE OF FAT ON BONE MEASUREMENTS WITH DUAL-ENERGY ABSORPTIOMETRY [J].
HANGARTNER, TN ;
JOHNSTON, CC .
BONE AND MINERAL, 1990, 9 (01) :71-81