COUPLED GAS-CHROMATOGRAPHY ATOMIC-ABSORPTION SPECTROMETRY USING SEMIENCLOSED TUBULAR ATOMIZERS - THEORETICAL-ANALYSIS OF DETECTOR PERFORMANCE-CHARACTERISTICS

被引:12
作者
BAXTER, DC
FRECH, W
机构
关键词
GAS CHROMATOGRAPHY; ATOMIC ABSORPTION SPECTROMETRY; GRAPHITE AND QUARTZ TUBE ATOMIZERS; DETECTOR RESPONSE MODEL AND PERFORMANCE CHARACTERISTICS; SPECIATION;
D O I
10.1039/an9931800495
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the determination of specific organometallic compounds in various environmental samples, coupled gas chromatography-atomic absorption spectrometry (GC-AAS) has proved to be a useful instrumental combination. However, to enable the optimum dimensions and operating conditions of the atomizer to be identified requires consideration of the theoretical aspects of GC-AAS detector performance. In this work, expressions are derived to describe the relative values of the detector sensitivity (peak height), and chromatographic efficiency and resolution in terms of the ratio between the residence time of the analyte in the atomizer and the standard deviation of the (assumed) Gaussian peak eluting from the GC system (tau(R)/sigma(G)). The greatest detector sensitivity is obtained at high tau(R)/sigma(G) values, but at the expense of degraded separation capabilities. Recommendations are given for the design of GC-AAS systems providing the best possible performance characteristics. A detector response model is also presented for predicting characteristic mass values (peak height and peak area) provided by GC-AAS systems and verified using literature data and experimental results.
引用
收藏
页码:495 / 504
页数:10
相关论文
共 41 条
[21]  
GUIBIN J, 1989, J ANAL ATOM SPECTROM, V4, P315
[22]  
Harrison R. M., 1989, ENV ANAL USING CHROM
[23]   DETERMINATION OF TIN(IV) AND ORGANOTIN COMPOUNDS IN NATURAL-WATERS, COASTAL SEDIMENTS AND MACRO ALGAE BY ATOMIC-ABSORPTION SPECTROMETRY [J].
HODGE, VF ;
SEIDEL, SL ;
GOLDBERG, ED .
ANALYTICAL CHEMISTRY, 1979, 51 (08) :1256-1259
[24]   SAMPLING AND EXTRA-COLUMN EFFECTS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - INFLUENCE OF PEAK SKEW ON PLATE COUNT CALCULATIONS [J].
KIRKLAND, JJ ;
YAU, WW ;
STOKLOSA, HJ ;
DILKS, CH .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1977, 15 (08) :303-316
[25]  
LEE ML, 1984, OPEN TUBULAR COLUMN, P14
[26]  
Lvov B.V., 1970, ATOMIC ABSORPTION SP
[27]   THEORETICAL CALCULATION OF THE CHARACTERISTIC MASS IN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
LVOV, BV ;
NIKOLAEV, VG ;
NORMAN, EA ;
POLZIK, LK ;
MOJICA, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (10) :1043-1053
[28]   RECENT ADVANCES IN ABSOLUTE ANALYSIS BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
LVOV, BV .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (07) :633-655
[29]  
Marrero T. R., 1972, Journal of Physical and Chemical Reference Data, V1, P3, DOI 10.1063/1.3253094
[30]   INSTRUMENTAL PEAK DISTORTION .I. RELAXATION TIME EFFECTS [J].
MCWILLIAM, IG ;
BOLTON, HC .
ANALYTICAL CHEMISTRY, 1969, 41 (13) :1755-+