INTERSTITIAL LUNG-DISEASE - IMPACT OF POSTPROCESSING IN DIGITAL STORAGE PHOSPHOR IMAGING

被引:48
作者
SCHAEFER, CM
GREENE, R
LLEWELLYN, HJ
MROSE, HE
PILESPELLMAN, EA
RUBENS, JR
LINDEMANN, SR
机构
[1] MASSACHUSETTS GEN HOSP,DEPT RADIOL,FRUIT ST,BOSTON,MA 02114
[2] HARVARD UNIV,SCH MED,BOSTON,MA 02115
关键词
DIAGNOSTIC RADIOLOGY; OBSERVER PERFORMANCE; LUNG; DISEASES; RADIOGRAPHY; DIGITAL; RECEIVER OPERATING CHARACTERISTIC CURVE (ROC);
D O I
10.1148/radiology.178.3.1994410
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The ability to resolve the fine linear structures of interstitial lung disease is one measure of the limiting performance characteristics of an imaging system. Conventional screen-film radiography was compared with six algorithms of isodose storage phosphor digital radiography (0.2-mm x 10-bit pixel matrix) in the detection of interstitial lung abnormality documented by means of computed tomography in 40 patients with abnormalities and 25 healthy control subjects. Performance was evaluated with an analysis of variance (the Fisher paired comparison test; P < .05) of the average receiver operating characteristic area of 2,730 observations by six readers. The moderately and the more markedly high-frequency edge-enhanced algorithms of storage phosphor digital radiographs were equivalent in performance to screen-film radiography. The default mode, low- and medium-frequency edge-enhanced algorithms, and gray scale reversed mode of storage phosphor digital radiography were inferior to screen-film radiography. The authors conclude that high-frequency edge-enhanced algorithms can perform as well as screen-film radiography in the detection of interstitial disease.
引用
收藏
页码:733 / 738
页数:6
相关论文
共 24 条
[11]   SPATIAL-RESOLUTION REQUIREMENTS FOR DIGITAL CHEST RADIOGRAPHS - AN ROC STUDY OF OBSERVER PERFORMANCE IN SELECTED CASES [J].
LAMS, PM ;
COCKLIN, ML .
RADIOLOGY, 1986, 158 (01) :11-19
[12]   DIGITAL RADIOGRAPHY OF SUBTLE PULMONARY ABNORMALITIES - AN ROC STUDY OF THE EFFECT OF PIXEL SIZE ON OBSERVER PERFORMANCE [J].
MACMAHON, H ;
VYBORNY, CJ ;
METZ, CE ;
DOI, K ;
SABETI, V ;
SOLOMON, SL .
RADIOLOGY, 1986, 158 (01) :21-26
[13]  
MacMahon H., 1985, Proceedings of the SPIE - The International Society for Optical Engineering, V555, P246, DOI 10.1117/12.949500
[14]   DIGITAL CHEST RADIOGRAPHY - EFFECT ON DIAGNOSTIC-ACCURACY OF HARD COPY, CONVENTIONAL VIDEO, AND REVERSED GRAY SCALE VIDEO DISPLAY FORMATS [J].
MACMAHON, H ;
METZ, CE ;
DOI, K ;
KIM, T ;
GIGER, ML ;
CHAN, HP .
RADIOLOGY, 1988, 168 (03) :669-673
[15]   BASIC PRINCIPLES OF ROC ANALYSIS [J].
METZ, CE .
SEMINARS IN NUCLEAR MEDICINE, 1978, 8 (04) :283-298
[17]  
METZ CE, 1984, INFORMATION PROCESSI, P432
[18]  
Metz CE, 1986, MULTIPLE REGRESSION, P365
[19]   HIGH-FREQUENCY EDGE ENHANCEMENT IN THE DETECTION OF FINE PULMONARY LINES - PARITY BETWEEN STORAGE PHOSPHOR DIGITAL IMAGES AND CONVENTIONAL CHEST RADIOGRAPHY [J].
OESTMANN, JW ;
GREENE, R ;
RUBENS, JR ;
PILESPELLMAN, E ;
HALL, D ;
ROBERTSON, C ;
LLEWELLYN, HJ ;
MCCARTHY, KA ;
POTSAID, M ;
WHITE, G .
INVESTIGATIVE RADIOLOGY, 1989, 24 (09) :643-646
[20]   DIGITAL STORAGE PHOSPHOR IMAGING VERSUS CONVENTIONAL FILM RADIOGRAPHY IN CT-DOCUMENTED CHEST DISEASE [J].
SCHAEFER, CM ;
GREENE, R ;
OESTMANN, JW ;
HALL, DA ;
LLEWELLYN, HJ ;
MCCARTHY, KA ;
PILESPELLMAN, ER ;
RUBENS, JR .
RADIOLOGY, 1990, 174 (01) :207-210