SEPARATION OF POLYBUTADIENE DEPENDING ON ISOMERIC STRUCTURES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:11
作者
SATO, H
SASAKI, M
OGINO, K
机构
[1] Department of Material Systems Engineering, Tokyo University of Agriculture and Technology
关键词
POLYBUTADIENE; ISOMERIC STRUCTURE; HIGH PERFORMANCE; LIQUID CHROMATOGRAPHY; SEPARATION; ADSORPTION; PHASE SEPARATION;
D O I
10.1295/polymj.23.23
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Polybutadiene was separated by isomeric structure using high performance liquid chromatography. With reversed-phase mode using a cross-linked styrene gel as a stationary phase and a mixture of acetonitrile and dichloromethane as an eluent, the polymer was separated by phase separation mechanism. With a cross-linked acrylamide gel and a mixture of hexane and dichloromethane (normal phase), the samples were eluted in order of 1,2 (vinyl), cis-1,4, and trans-1,4 structure by adsorption mechanism. The resolution by adsorption mechanism was better than one by phase separation mechanism. If acrylonitrile gel was used as stationary phase in the normal phase, samples were adsorbed only weakly to the gel and the resolution was not good.
引用
收藏
页码:23 / 27
页数:5
相关论文
共 30 条
[11]   INVESTIGATION OF COPOLYMERS OF STYRENE AND ETHYL METHACRYLATE BY SIZE-EXCLUSION CHROMATOGRAPHY AND GRADIENT HPLC .2. GRADIENT HPLC USING REVERSED-PHASE CONDITIONS [J].
GLOCKNER, G ;
STICKLER, M ;
WUNDERLICH, W .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 330 (01) :46-49
[12]   GRADIENT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF STATISTICAL AND BLOCK COPOLYMERS OF STYRENE AND TERT-BUTYL METHACRYLATE [J].
GLOCKNER, G ;
MULLER, AHE .
JOURNAL OF APPLIED POLYMER SCIENCE, 1989, 38 (09) :1761-1774
[13]   HP PRECIPITATION CHROMATOGRAPHY OF STYRENE-ACRYLONITRILE CO-POLYMERS [J].
GLOCKNER, G ;
KROSCHWITZ, H ;
MEISSNER, C .
ACTA POLYMERICA, 1982, 33 (10) :614-616
[14]  
GLOCKNER G, 1984, MACROMOLECULES, V17, P962
[15]   2-DIMENSIONAL ANALYSIS OF COPOLYMERS BY SIZE-EXCLUSION CHROMATOGRAPHY AND GRADIENT-ELUTION REVERSED-PHASE PRECIPITATION CHROMATOGRAPHY [J].
GLOCKNER, G ;
VANDENBERG, JHM ;
MEIJERINK, NLJ ;
SCHOLTE, TG ;
KONINGSVELD, R .
JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC) :615-624
[16]   PRECIPITATION AND ADSORPTION PHENOMENA IN POLYMER CHROMATOGRAPHY [J].
GLOCKNER, G ;
VANDENBERG, JHM .
JOURNAL OF CHROMATOGRAPHY, 1986, 352 :511-522
[17]  
GLOCKNER G, 1989, J APPL POLYM SCI APP, V43, P39
[18]   SEPARATION OF STYRENE METHYL-METHACRYLATE RANDOM COPOLYMERS ACCORDING TO CHEMICAL-COMPOSITION AND MOLECULAR-SIZE BY LIQUID ADSORPTION AND SIZE EXCLUSION CHROMATOGRAPHY [J].
MORI, S ;
UNO, Y ;
SUZUKI, M .
ANALYTICAL CHEMISTRY, 1986, 58 (02) :303-307
[19]   SEPARATION AND CHARACTERIZATION OF LOW-CONVERSION POLY(STYRENE-CO-METHYL METHACRYLATE) BY LIQUID ADSORPTION CHROMATOGRAPHY [J].
MORI, S ;
UNO, Y .
JOURNAL OF APPLIED POLYMER SCIENCE, 1987, 34 (08) :2689-2699
[20]   OPERATIONAL VARIABLES FOR THE SEPARATION OF STYRENE METHYL-METHACRYLATE COPOLYMERS ACCORDING TO CHEMICAL-COMPOSITION BY LIQUID ADSORPTION CHROMATOGRAPHY [J].
MORI, S ;
UNO, Y .