摘要
Poly(vinyl chloride) membrane CHEMFETs incorporating a novel calix[4]arene derivative (1). novel calix[6]arene derivatives (3, 4, 5, 6 and 7), phosphate derivatives of p-tert-butylcalix[4]arene (2) or p-tert-butylcalix[6] arene (8) with variable amounts of hydrophobic anions [potassium tetrakis(4-chlorophenyl)borate (KTCTPB)] have been tested for their response to guanidinium ions in the presence of the interfering ions Na+, K+, NH,+ and Ca2+. The best guanidinium selectivity has been obtained for the CHEMFET based on the 1.3,5-triamide derivative of p-tert-butylcalix[6]arene (4), with dibutyl phthalate as solvent mediator, and 50 mol% KTCTPB with respect to the ionophore. The selectivity coefficients (log K-Gu.j(pot)) are the highest reported for guanidinium ions in a potentiometric sensor. The CHEMFETs show an almost ideal Nernstian response in the linear range (slope 58-60 mV decade(-1)).
引用
收藏
页码:677 / 681
页数:5
相关论文
共 28 条
[1]   COMPARATIVE-STUDY OF POLYETHER-TYPE NEUTRAL CARRIERS FOR THE POTENTIOMETRIC SENSING OF GUANIDINIUM IONS [J].
ASSUBAIE, FN ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1989, 114 (12) :1545-1550
[2]   GUANIDINIUM ION-SELECTIVE ELECTRODES BASED ON DIBENZO-27-CROWN-9 AND TETRAPHENYLBORATE [J].
ASSUBAIE, FN ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1988, 113 (01) :61-64
[3]  
ASSUBAIE FN, 1987, PORT ELECTROCHIM ACT, V5, P103
[4]   TORAND SYNTHESIS BY TRIMERIZATION - NEW RECEPTORS FOR GUANIDINIUM [J].
BELL, TW ;
LIU, J .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 1990, 29 (08) :923-925
[5]   THE OPERATION OF AN ISFET AS AN ELECTRONIC DEVICE [J].
BERGVELD, P .
SENSORS AND ACTUATORS, 1981, 1 (01) :17-29
[6]   GUANIDINIUM-SELECTIVE PVC MEMBRANE ELECTRODES BASED ON CROWN ETHERS [J].
BOCHENSKA, M ;
BIERNAT, JF .
ANALYTICA CHIMICA ACTA, 1984, 162 (AUG) :369-371
[7]  
BRUNINK JAJ, 1992, RECL TRAV CHIM PAY B, V111, P511
[8]   CHEMICALLY MODIFIED FIELD-EFFECT TRANSISTORS - A SODIUM-ION SELECTIVE SENSOR BASED ON CALIX[4]ARENE RECEPTOR MOLECULES [J].
BRUNINK, JAJ ;
HAAK, JR ;
BOMER, JG ;
REINHOUDT, DN ;
MCKERVEY, MA ;
HARRIS, SJ .
ANALYTICA CHIMICA ACTA, 1991, 254 (1-2) :75-80
[9]  
CASNATI A, 1992, ISRAEL J CHEM, V32, P79
[10]  
COBBEN PLH, 1992, THESIS U TWENTE, pCH3