EVALUATION OF AN ULTRASONIC NEBULIZER FOR SAMPLE INTRODUCTION IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY

被引:21
作者
CASTILLANO, TM
VELA, NP
CARUSO, JA
STORY, WC
机构
[1] UNIV CINCINNATI,DEPT CHEM,CINCINNATI,OH 45221
[2] ENVIRONM HLTH RES & TESTING INC,CINCINNATI,OH 45245
关键词
INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY; ULTRASONIC NEBULIZER; MATRIX EFFECT;
D O I
10.1039/ja9920700807
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A low cost ultrasonic nebulizer has been designed using a forced air cooling method. The performance of this ultrasonic nebulizer in inductively coupled plasma atomic emission spectrometry has been evaluated and compared with a concentric nebulizer and a glass frit nebulizer. Higher signal-to-background ratios have been achieved for the ultrasonic nebulizer compared with the concentric and glass frit nebulizers. Detection limits and sensitivity have been improved by approximately one and two orders of magnitude, respectively. In addition, the response time of the ultrasonic nebulizer is comparable to those of the other types of nebulizers studied; a relative standard deviation of 3-5% for the ultrasonic nebulizer. Tests were also conducted to determine the effects of a high matrix sample such as synthetic ocean water.
引用
收藏
页码:807 / 811
页数:5
相关论文
共 13 条
[1]   EVALUATION OF THE GRID-TYPE NEBULIZER FOR THE INTRODUCTION OF HIGH DISSOLVED SALT AND HIGH SOLIDS CONTENT SOLUTIONS INTO THE INDUCTIVELY COUPLED PLASMA [J].
BROTHERTON, T ;
CARUSO, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (07) :695-698
[2]  
CHAN S, 1991, ICP INFORM NEWSL, V16, P436
[3]   DUAL-BEAM, LIGHT-SCATTERING INTERFEROMETRY FOR SIMULTANEOUS MEASUREMENTS OF DROPLET-SIZE AND VELOCITY DISTRIBUTIONS OF AEROSOLS FROM COMMONLY USED NEBULIZERS [J].
CLIFFORD, RH ;
ISHII, I ;
MONTASER, A ;
MEYER, GA .
ANALYTICAL CHEMISTRY, 1990, 62 (04) :390-394
[4]   CONVERSION OF AN ULTRASONIC HUMIDIFIER TO A CONTINUOUS-TYPE ULTRASONIC NEBULIZER FOR ATOMIC SPECTROMETRY [J].
CLIFFORD, RH ;
MONTASER, A ;
DOLAN, SP ;
CAPAR, SG .
ANALYTICAL CHEMISTRY, 1990, 62 (24) :2745-2749
[5]  
DENTON MB, 1990, SAMPLE INTRO ATOMIC, V4, pCH4
[6]   ULTRASONIC NEBULIZATION OF LIQUID SAMPLES FOR ANALYTICAL INDUCTIVELY COUPLED PLASMA-ATOMIC SPECTROSCOPY - AN UPDATE [J].
FASSEL, VA ;
BEAR, BR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (10) :1089-1113
[7]   MODIFIED ULTRASONIC NEBULIZER FOR INDUCTIVELY COUPLED ARGON PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
GOULDEN, PD ;
ANTHONY, DHJ .
ANALYTICAL CHEMISTRY, 1984, 56 (13) :2327-2329
[8]   AN EFFICIENT AND INEXPENSIVE ULTRASONIC NEBULIZER FOR ATOMIC SPECTROMETRY [J].
JIN, QH ;
ZHU, C ;
BRUSHWYLER, K ;
HIEFTJE, GM .
APPLIED SPECTROSCOPY, 1990, 44 (02) :183-186
[9]   MULTIELEMENT DETECTION LIMITS AND SAMPLE NEBULIZATION EFFICIENCIES OF AN IMPROVED ULTRASONIC NEBULIZER AND A CONVENTIONAL PNEUMATIC NEBULIZER IN INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROMETRY [J].
OLSON, KW ;
HAAS, WJ ;
FASSEL, VA .
ANALYTICAL CHEMISTRY, 1977, 49 (04) :632-637