ASYMMETRIC-ECHO, SHORT TE, RETROSPECTIVELY GATED MR-IMAGING OF THE HEART AND PULMONARY VESSELS

被引:9
作者
RICHARDSON, DB [1 ]
MACFALL, JR [1 ]
SOSTMAN, HD [1 ]
SPRITZER, CE [1 ]
机构
[1] DUKE UNIV,MED CTR,DEPT RADIOL,BOX 3302,BRYAN RES BLDG,RM 160,DURHAM,NC 27710
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1994年 / 4卷 / 02期
关键词
BLOOD VESSELS; GRADIENT WAVE-FORMS; HEART; ANATOMY; IMAGE PROCESSING; PULMONARY ARTERIES; PULSE SEQUENCES; RAPID IMAGING;
D O I
10.1002/jmri.1880040205
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Although retrospectively cardiac-gated (cine) magnetic resonance imaging has shown promise for large-vessel pulmonary vascular imaging, it has not been able to depict the peripheral pulmonary vasculature, where signal is dephased because of susceptibility and/or motion artifacts. The authors developed a cine pulse sequence that uses asymmetric echoes and radio-frequency envelopes to achieve reduced gradient moments and a short TE, thereby reducing signal losses due to disordered flow and susceptibility effects. The effects of TE (2.8-12 msec) and the degree of echo symmetry as measured by the echo symmetry fraction (ESF) (0.6-1.0) are considered in the pulmonary vasculature and the heart. In pulmonary vessels, the signal-to-noise ratio nearly doubled as TE was decreased from 12 to 2.8 msec, but there was only about a 15% difference as the ESF decreased from 1.0 to 0.6, consistent with T2* losses dominating gradient moment dephasing. At a TE of 2.8 msec, the sequence improves visualization of pulmonary vessels and may be helpful for diagnosing pulmonary emboli. In the heart, however, the contrast-to-noise ratio between blood land cardiac tissue decreased by 30% as TE decreased from 12 to 2.8 msec and was not affected by changes in ESF. Flow artifacts in the cardiac blood pool, including those that can aid in diagnosis (eg. signal loss due to ''jet'' flow), are much less pronounced when a small ESF and short TE are used, making this sequence less attractive for investigation of cardiac flow irregularities. The reduced flow artifacts in this case, however, permit excellent depiction of gross cardiac anatomy.
引用
收藏
页码:131 / 137
页数:7
相关论文
共 10 条
[1]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[2]  
BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
[3]  
EVANS AJ, 1993, AM J NEURORADIOL, V14, P721
[4]  
Glover G H, 1988, Magn Reson Annu, P299
[5]   NMR RELAXATION-TIMES OF BLOOD - DEPENDENCE ON FIELD-STRENGTH, OXIDATION-STATE, AND CELL INTEGRITY [J].
GOMORI, JM ;
GROSSMAN, RI ;
YUIP, C ;
ASAKURA, T .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (04) :684-690
[6]   NUCLEAR MAGNETIC-RESONANCE IMAGING OF THE CARDIOVASCULAR-SYSTEM - NORMAL AND PATHOLOGIC FINDINGS [J].
HERFKENS, RJ ;
HIGGINS, CB ;
HRICAK, H ;
LIPTON, MJ ;
CROOKS, LE ;
LANZER, P ;
BOTVINICK, E ;
BRUNDAGE, B ;
SHELDON, PE ;
KAUFMAN, L .
RADIOLOGY, 1983, 147 (03) :749-759
[7]   SIGNAL-TO-NOISE, RESOLUTION, AND BIAS FUNCTION-ANALYSIS OF ASYMMETRIC SAMPLING WITH ZERO-PADDED MAGNITUDE FT RECONSTRUCTION [J].
HURST, GC ;
HUA, JM ;
SIMONETTI, OP ;
DUERK, JL .
MAGNETIC RESONANCE IN MEDICINE, 1992, 27 (02) :247-269
[8]   MAGNETIC-RESONANCE ANGIOGRAPHY BY SELECTIVE INVERSION RECOVERY USING A COMPACT GRADIENT ECHO SEQUENCE [J].
NISHIMURA, DG ;
MACOVSKI, A ;
JACKSON, JI ;
HU, RS ;
STEVICK, CA ;
AXEL, L .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (01) :96-103
[9]   CINE GRADIENT-REFOCUSED MR IMAGING OF CENTRAL PULMONARY EMBOLI [J].
POSTERARO, RH ;
SOSTMAN, HD ;
SPRITZER, CE ;
HERFKENS, RJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) :465-468
[10]   VOLUME MR ANGIOGRAPHY - METHODS TO ACHIEVE VERY SHORT ECHO TIMES [J].
SCHMALBROCK, P ;
YUAN, C ;
CHAKERES, DW ;
KOHLI, J ;
PELC, NJ .
RADIOLOGY, 1990, 175 (03) :861-865