SCATTER CORRECTION IN 3-D PET

被引:16
作者
LERCHER, MJ [1 ]
WIENHARD, K [1 ]
机构
[1] MAX PLANCK INST NEUROL RES,D-50931 COLOGNE,GERMANY
关键词
D O I
10.1109/42.363103
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Modern multiring positron emission tomographs allow the acquisition of 3-D data sets to increase their sensitivity. A substantial part of this data is due to scattered radiation. We describe the experimental dependence of point source scatter distributions on energy window setting, source location, and scatter volume in geometries relevant for brain studies. The point source scatter distribution was parametrized accurately by a broad, 2-D Gaussian, which included a shift parameter to account for asymmetry of the scatter medium relative to the source. This parametrization was used to formulate two fast scatter correction algorithms suitable for brain scans. In both algorithms, a 2-D subset of the measured projections was transformed into a scatter projection, An image of the 3-D scatter distribution was reconstructed using 2-D algorithms. It was then subtracted from the total (true + scattered) 3-D image. Both algorithms were implemented in different combinations with the additional attenuation correction and were tested on point source and phantom measurements. It was shown that, for the situation typical for brain scans, reconstructed scatter fractions could be reduced to 5% or less.
引用
收藏
页码:649 / 657
页数:9
相关论文
共 12 条
[1]   CORRECTION FOR SCATTERED RADIATION IN A RING DETECTOR POSITRON CAMERA BY INTEGRAL TRANSFORMATION OF THE PROJECTIONS [J].
BERGSTROM, M ;
ERIKSSON, L ;
BOHM, C ;
BLOMQVIST, G ;
LITTON, J .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (01) :42-50
[2]  
CHERRY S R, 1992, Journal of Nuclear Medicine, V33, P879
[3]   3D PET USING A CONVENTIONAL MULTISLICE TOMOGRAPH WITHOUT SEPTA [J].
CHERRY, SR ;
DAHLBOM, M ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) :655-668
[4]  
GROOTOONK S, 1990, THESIS U SURREY, P24
[5]   SCATTER CORRECTION IN THE TRANSAXIAL SLICES OF A WHOLE-BODY POSITRON EMISSION TOMOGRAPH [J].
HOVERATH, H ;
KUEBLER, WK ;
OSTERTAG, HJ ;
DOLL, J ;
ZIEGLER, SI ;
KNOPP, MV ;
LORENZ, WJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (06) :717-728
[6]  
KARP JS, 1991, J NUCL MED, V32, P2342
[7]   NOISE IDENTIFICATION AND REMOVAL IN POSITRON IMAGING-SYSTEMS [J].
KING, PH ;
HUBNER, K ;
GIBBS, W ;
HOLLOWAY, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) :148-151
[8]  
LERCHER MJ, 1992, THESIS U COLOGNE
[9]   CROSS-PLANE SCATTERING CORRECTION - POINT-SOURCE DECONVOLUTION IN PET [J].
SHAO, LX ;
KARP, JS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :234-239
[10]   FULLY 3-DIMENSIONAL RECONSTRUCTION FOR A PET CAMERA WITH RETRACTABLE SEPTA [J].
TOWNSEND, DW ;
GEISSBUHLER, A ;
DEFRISE, M ;
HOFFMAN, EJ ;
SPINKS, TJ ;
BAILEY, DL ;
GILARDI, MC ;
JONES, T .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (04) :505-512