SYNTHETIC-APERTURE IMAGING FOR SMALL-SCALE SYSTEMS

被引:491
作者
KARAMAN, M
LI, PC
ODONNELL, M
机构
[1] ACUSON CORP,MT VIEW,CA
[2] UNIV MICHIGAN,DEPT ELECT ENGN & COMP SCI,ANN ARBOR,MI 48109
基金
美国国家卫生研究院;
关键词
D O I
10.1109/58.384453
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Multi-element synthetic aperture imaging methods suitable for applications with severe cost and size limitations are explored. Array apertures are synthesized using an active multi-element receive subaperture and a multi-element transmit subaperture defocused to emulate a single-element spatial response with high acoustic power. Echo signals are recorded independently by individual elements of the receive subaperture. Each method uses different spatial frequencies and acquisition strategies for imaging, and therefore different sets of active transmit/receive element combinations. Following acquisition, image points are reconstructed using the complete data set with full dynamic focus on both transmit and receive. Various factors affecting image quality have been evaluated and compared to conventional imagers through measurements with a 3.5 MHz, 128-element transducer array on different gel phantoms. Multi-element synthetic aperture methods achieve higher electronic signal to noise ratio and better contrast resolution than conventional synthetic aperture techniques, approaching conventional phased array performance.
引用
收藏
页码:429 / 442
页数:14
相关论文
共 42 条
[11]   VLSI CIRCUITS FOR ADAPTIVE DIGITAL BEAMFORMING IN ULTRASOUND IMAGING [J].
KARAMAN, M ;
ATALAR, A ;
KOYMEN, H .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) :711-720
[12]  
KARAMAN M, 1992, ACOUSTICAL IMAGING, V19
[13]   SYNTHETIC APERTURE IMAGING USING A LAGRANGE BASED FILTERING TECHNIQUE [J].
LI, PC ;
ODONNELL, M .
ULTRASONIC IMAGING, 1992, 14 (04) :354-366
[14]   IMPROVED DETECTABILITY WITH BLOCKED ELEMENT COMPENSATION [J].
LI, PC ;
ODONNELL, M .
ULTRASONIC IMAGING, 1994, 16 (01) :1-18
[15]   ULTRASONIC PHASED-ARRAY SCANNER WITH DIGITAL ECHO SYNTHESIS FOR DOPPLER ECHOCARDIOGRAPHY [J].
LUTOLF, RM ;
VIELI, A ;
BASLER, S .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1989, 36 (05) :494-506
[16]  
MARAGOS P, 1989, 1989 P INT C AC SPEE, P1568
[17]  
MEUNIER J, 1993, P SOC PHOTO-OPT INS, V1896, P381, DOI 10.1117/12.154611
[18]  
MORCIRA A, 1992, IEEE T GEOSCI REMOTE, V30, P714
[19]   A NEW SYNTHETIC-APERTURE FOCUSING METHOD FOR ULTRASONIC B-SCAN IMAGING BY THE FOURIER-TRANSFORM [J].
NAGAI, K .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (04) :531-536
[20]   SYNTHETIC RECEIVE APERTURE IMAGING WITH PHASE CORRECTION FOR MOTION AND FOR TISSUE INHOMOGENEITIES .1. BASIC PRINCIPLES [J].
NOCK, LF ;
TRAHEY, GE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (04) :489-495