CARDIAC ECHO-PLANAR MR-IMAGING - COMPARISON OF SINGLE-SHOT AND MULTIPLE-SHOT TECHNIQUES

被引:28
作者
WETTER, DR [1 ]
MCKINNON, GC [1 ]
DEBATIN, JF [1 ]
VONSCHULTHESS, GK [1 ]
机构
[1] UNIV ZURICH HOSP,DEPT RADIOL,CH-8091 ZURICH,SWITZERLAND
关键词
HEART; FLOW DYNAMICS; MR; MAGNETIC RESONANCE (MR); ECHO PLANAR; MYOCARDIUM; VENTRICLES;
D O I
10.1148/radiology.194.3.7862976
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the quality of cardiac images acquired with two- and four-shot echo-planar imaging (EPI) with that of images acquired with single-shot EPI. MATERIALS AND METHODS: Single-, two-, and four-shot EPI was performed to obtain axial images that traversed both cardiac ventricles. The subjects were 10 healthy men whose ages ranged from 22 to 38 years (mean, 27 years). The multiple-shot EPI data were acquired in snapshot (sequential) and cardiac-gated (nonsequential) modes. Image quality was compared by evaluation of the depiction of cardiac structures and analysis of signal intensity, contrast, and signal homogeneity. RESULTS: Multiple-shot EPI depicted the coronary and internal mammary arteries better than did single-shot EPI (P < .05). Intraventricular signal intensity was more homogeneous on multiple-shot images (P < .005). Cardiac-gated acquisition resulted in less image blurring and allowed acquisition of more phases per RR interval. CONCLUSION: Multiple-shot EPI rendered higher quality images than did single-shot EPI.
引用
收藏
页码:765 / 770
页数:6
相关论文
共 21 条
  • [1] INTERLEAVED ECHO-PLANAR IMAGING ON A STANDARD MRI SYSTEM
    BUTTS, K
    RIEDERER, SJ
    EHMAN, RL
    THOMPSON, RM
    JACK, CR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) : 67 - 72
  • [2] ANALYSIS OF FLOW EFFECTS IN ECHO-PLANAR IMAGING
    BUTTS, K
    RIEDERER, SJ
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03): : 285 - 293
  • [3] ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM
    BUTTS, K
    RIEDERER, SJ
    EHMAN, RL
    FELMLEE, JP
    GRIMM, RC
    [J]. RADIOLOGY, 1993, 189 (01) : 259 - 264
  • [4] REAL-TIME MOVIE IMAGING FROM A SINGLE CARDIAC CYCLE BY NMR
    CHAPMAN, B
    TURNER, R
    ORDIDGE, RJ
    DOYLE, M
    CAWLEY, M
    COXON, R
    GLOVER, P
    MANSFIELD, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (03) : 246 - 254
  • [5] CHIEN D, 1991, Magnetic Resonance Quarterly, V7, P31
  • [6] Cho ZH, 1987, 6TH P SMRM ANN M, P912
  • [7] NORMAL HEART - EVALUATION WITH ECHO-PLANAR MR-IMAGING
    DAVIS, CP
    MCKINNON, GC
    DEBATIN, JF
    WETTER, D
    EICHENBERGER, AC
    DUEWELL, S
    VONSCHULTHESS, GK
    [J]. RADIOLOGY, 1994, 191 (03) : 691 - 696
  • [8] SEGMENTED TURBOFLASH - METHOD FOR BREATH-HOLD MR IMAGING OF THE LIVER WITH FLEXIBLE CONTRAST
    EDELMAN, RR
    WALLNER, B
    SINGER, A
    ATKINSON, DJ
    SAINI, S
    [J]. RADIOLOGY, 1990, 177 (02) : 515 - 521
  • [9] CONTRAST-ENHANCED ECHO-PLANAR MR-IMAGING OF MYOCARDIAL PERFUSION - PRELIMINARY-STUDY IN HUMANS
    EDELMAN, RR
    LI, W
    [J]. RADIOLOGY, 1994, 190 (03) : 771 - 777
  • [10] ISCHEMIC-HEART-DISEASE - ASSESSMENT WITH GADOLINIUM-ENHANCED ULTRAFAST MR-IMAGING AND DIPYRIDAMOLE STRESS
    EICHENBERGER, AC
    SCHUIKI, E
    KOCHLI, VD
    AMANN, FW
    MCKINNON, GC
    VONSCHULTHESS, GK
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03) : 425 - 431