DEMONSTRATION OF NUCLEAR-MAGNETIC-RESONANCE IMAGING FOR VOID DETECTION IN CARBON-FIBER REINFORCED POLYMER COMPOSITES, AND COMPARISON WITH ULTRASOUND METHODS

被引:10
作者
JEZZARD, P
WIGGINS, CJ
CARPENTER, TA
HALL, LD
BARNES, JA
JACKSON, P
CLAYDEN, NJ
机构
[1] UNIV CAMBRIDGE,SCH CLIN MED,HERCHEL SMITH LAB MED CHEM,UNIV FORVIE SITE,ROBINSON WAY,CAMBRIDGE CB2 2PZ,ENGLAND
[2] ICI COMPOSITES INC,TEMPE,AZ 85284
[3] ICI PLC,WILTON MAT RES CTR,MIDDLESBROUGH TS6 8JE,CLEVELAND,ENGLAND
关键词
D O I
10.1007/BF00576286
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Nuclear magnetic resonance imaging has been used as a method of void detection in carbon-fibre reinforced polymer composites. This is accomplished by observation of signal from water molecules which have ingressed into surface-connected defect regions within the polymer composite. Problems associated with the conductivity of these samples are discussed, along with methods of overcoming those difficulties.
引用
收藏
页码:6365 / 6370
页数:6
相关论文
共 20 条
[11]   CURING OF CARBON-FIBER REINFORCED EPOXY-RESIN - NONINVASIVE VISCOSITY MEASUREMENT BY NMR IMAGING [J].
JACKSON, P .
JOURNAL OF MATERIALS SCIENCE, 1992, 27 (05) :1302-1306
[12]   DEFECT DETECTION IN CARBON-FIBER COMPOSITE STRUCTURES BY MAGNETIC-RESONANCE-IMAGING [J].
JACKSON, P ;
BARNES, JA ;
CLAYDEN, NJ ;
CARPENTER, TA ;
HALL, LD ;
JEZZARD, P .
JOURNAL OF MATERIALS SCIENCE LETTERS, 1990, 9 (10) :1165-1168
[13]   MAGNETIC-RESONANCE-IMAGING STUDIES OF THE POLYMERIZATION OF METHYLMETHACRYLATE [J].
JACKSON, P ;
CLAYDEN, NJ ;
WALTON, NJ ;
CARPENTER, TA ;
HALL, LD ;
JEZZARD, P .
POLYMER INTERNATIONAL, 1991, 24 (03) :139-143
[14]  
JACKSON P, 1991, 36TH P INT SAMPE S S
[15]  
JACKSON P, 1991, 12TH P INT SAMPE EUR
[16]  
JEZZARD P, 1991, POLYM COMMUN, V32, P74
[17]  
KRAUTKAMER J, 1969, ULTRASONIC TESTING M
[18]  
MANSFIELD P, 1982, ADV MAGNETIC RESON 2, V2
[19]  
WEBB AG, 1989, POLYM COMMUN, V30, P593
[20]  
[No title captured]