BLOOD-FLOW IN THE HUMAN ACHILLES-TENDON ASSESSED BY LASER-DOPPLER FLOWMETRY

被引:90
作者
ASTROM, M
WESTLIN, N
机构
[1] Section of Sports Medicine, Department of Orthopaedics, Malmö General Hospital, Lund University, Malmö
关键词
D O I
10.1002/jor.1100120214
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study evaluated microvascular perfusion in the human Achilles tendon by laser Doppler flowmetry (LDF) at rest, during vascular occlusion, and during passive stretch and isometric contraction of the triceps surae. In 40 healthy volunteers, an intratendinous needle probe was introduced 5 mm above the distal insertion, at the midportion, and at the musculotendinous junction of both legs. Values were obtained at rest and during temporary vascular occlusion. Twenty-eight of the subjects also were assessed during physical provocation by passive stretch and isometric contraction of the triceps surae. Blood flow was significantly lower near the calcaneal insertion but otherwise was distributed evenly in the tendon. The output signal showed a pulsatile variation synchronous with heart activity, and temporary vascular occlusion always caused a pronounced reduction in LDF values. Passive stretch and isometric contraction induced a progressive decline in LDF values as tension increased. Hyperemia often appeared after contraction. Tendon blood flow was higher in women and decreased with increasing age.