TISSUE-RESPONSE TO PERCUTANEOUS IMPLANTS IN RABBITS

被引:33
作者
JANSEN, JA
VANDERWAERDEN, JPCM
VANDERLUBBE, HBM
DEGROOT, K
机构
[1] Department of Biomaterials, ACTA-Free University, Amsterdam, 1007 MC
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1990年 / 24卷 / 03期
关键词
D O I
10.1002/jbm.820240303
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study reports on certain aspects of wound‐healing around percutaneous implants. Plasma‐sprayed and dense hydroxylapatite, titanium, and carbon test implants were inserted into the tibia and the cranium of 12 rabbits. Four and 8 months after insertion, the animals were sacrificed and the implants with their surrounding tissues were processed histologically. Light‐ and transmission electron microscopic investigations were performed. It is found that direct and indirect boneanchoring favors the longevity of percutaneous implants. No differences in tissue reaction between the various implant materials were observed. Copyright © 1990 John Wiley & Sons, Inc.
引用
收藏
页码:295 / 307
页数:13