PARATHYROID IMAGING

被引:46
作者
COAKLEY, AJ
机构
[1] Department of Nuclear Medicine, Kent and Canterbury Hospital, Canterbury, Kent
关键词
D O I
10.1097/00006231-199507000-00002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Developments in technology mean that it is now possible to localize abnormal parathyroid glands by a variety of imaging methods. There remain a number of unresolved issues. With all commonly used methods (radionuclide imaging, ultrasound, computed tomography and magnetic resonance imaging), there are wide variations in sensitivity of detection of glands, and in many cases this variation is not explained satisfactorily. The necessity for imaging is questioned by many parathyroid surgeons, particularly before a first operation. However, parathyroid surgery is itself changing, with a trend towards more limited neck exploration, which requires localization of the glands pre-operatively. This review describes the methods available for localizing parathyroid glands, with their advantages and limitations, and discusses the role of the techniques prior to surgery.
引用
收藏
页码:522 / 533
页数:12
相关论文
共 96 条
[11]  
Ell P.J., Todd-Pokropek A., Britton K.E., Localization of parathyroid adenomas by computer-assisted parathyroid scanning, Br J Surg, 62, pp. 553-555, (1975)
[12]  
Robinson P.J., Parathyroid scintigraphy revisited, Clin Radiol, 33, pp. 37-41, (1982)
[13]  
Waldorf J.C., Van Heerden J.A., Gorman CA et al. [75-Se] Selenomethionine scanning for parathyroid localization should be abandoned, Mayo Clin Proc, 59, pp. 534-537, (1984)
[14]  
Cann C.E., Prussin S.G., Possible Parathyroid Imaging Using Ga-67 and Other Aluminium Analogs J Nucl Med, 21, pp. 471-474, (1980)
[15]  
Iwase M., Shimizu Y., Kitahara H., Et al., Parathyroid Carcinoma Visualized by Gallium-67 Citrate Scintigraphy.] Nucl Med, 27, pp. 63-65, (1986)
[16]  
Zwas S.T., Czerniak A., Boruchowsky S., Et al., Preoperative Parathyroid Localization by Superimposed Iodine-131 Toluidine Blue and Technetium-99M Pertechnetate imag¬ing./Nucl Med, 28, pp. 298-307, (1987)
[17]  
Czerniak A., Zwas S.T., Shustik O., Et al., The use of radioiodinated toluidine blue for preoperative localization of parathyroid pathology, Surgery, 110, pp. 832-838, (1991)
[18]  
Blower P.J., Kettle A.G., O'doherty M.J., Collins R., Coakley A.J., 123I-methylene blue: An unsatisfactory parathyroid imaging agent, Nucl Med Commun, 13, pp. 522-527, (1992)
[19]  
Ferlin G., Borsato N., Camerani M., Et al., New Perspectives in Localising Enlarged Parathyroids by Technetium- Thallium Subtraction Scan. J Nucl Med, 24, pp. 438-441, (1983)