ANALYSIS OF BETA-AGONISTS IN URINE AND TISSUES BY CAPILLARY GAS CHROMATOGRAPHY-MASS SPECTROMETRY - IN-VIVO STUDY OF SALBUTAMOL DISPOSITION IN CALVES

被引:25
作者
MONTRADE, MP [1 ]
LEBIZEC, B [1 ]
MONTEAU, F [1 ]
ANDRE, F [1 ]
机构
[1] ECOLE NATL VET,MINIST AGR,LDH,F-44087 NANTES 03,FRANCE
来源
FOOD ADDITIVES AND CONTAMINANTS | 1995年 / 12卷 / 05期
关键词
BETA-2-AGONIST; SALBUTAMOL; GAS CHROMATOGRAPHY-MASS SPECTROMETRY; TISSUE RESIDUES; BOVINES;
D O I
10.1080/02652039509374351
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The fate of salbutamol sulphate given orally has been investigated in calves. The urinary excretion rate and the tissue distribution of this beta-agonistic drug were studied by capillary gas chromatography coupled to low resolution mass spectrometry (GC-LRMS) under electron impact (EI) ionization mode, using an hexadeuterated salbutamol analogue as the internal standard. The parent drug and metabolites were extracted via solid phase extraction (SPE) mixed-phase-containing disposable columns and analysed as their trimethylsilyl derivatives. A more efficient clean-up had to be carried out for tissue samples. An acidic precipitation followed by a liquid-liquid extraction were therefore performed before the SPE. Moreover, the problem of tissue digestion was elucidated by means of an ultrasonic probe. Samples were also analysed before and after enzymic hydrolysis using purified beta-glucuronidase and a mixture of beta-glucuronidase and arylsulphatase, to obtain evidence of phase II conjugation mechanisms. Both free salbutamol and conjugated metabolites were detected in urine and tissue samples. Except for liver or kidney, salbutamol was rapidly cleared from most tissues after a withdrawal period. The possible excretion of some phase I metabolites was also investigated, using further analyses under positive chemical ionization LRMS and high resolution mass spectrometry (HRMS).
引用
收藏
页码:625 / 636
页数:12
相关论文
共 31 条
[11]  
Hochhaus G., Mollmann H., Pharmacokinetic/pharmacodynamic characteristics of the β<sub>2</sub>-agonists terbutaline, salbutamol and feneterol, International Journal of Clinical Pharmacology, Therapy and Toxicology, 30, pp. 342-362, (1992)
[12]  
Hutchings M.J., Paull J.D., Morgan D.J., Determination of salbutamol in plasma by high performance liquid chromatography with fluorescence detection, Journal of Chromatography, 277, pp. 423-426, (1983)
[13]  
Leferink J.G., Dankers J., Maes R., A time saving method for the determination of the β-2 sympathomimetics terbutaline, salbutamol and fenoterol. Preliminary results, Journal of Chromatography, 229, pp. 217-221, (1982)
[14]  
Leyssens L., Driessen C., Jacobs A., Czech J., Raus J., Determination of β<sub>2</sub>-receptor agonists in bovine urine and liver by gas chromatography-tandem mass spectrometry, Journal of Chromatography, 564, pp. 515-527, (1991)
[15]  
Lindberg C., Jonsson S., Simultaneous determination of terbutaline and albutamol in plasma by selected ion monitoring, Biomedical Mass Spectrometry, 9, pp. 460-461, (1982)
[16]  
Loo J.C., Beaulieu N., Jordan N., Brien R., Ncgilveray I.J., A specific radio-immunoassay (RIA) for salbutamol (albuterol) in human plasma, Research Communications in Chemical Pathology and Pharmacology, 55, pp. 283-286, (1987)
[17]  
Martin L.E., Rees J., Tanner R., Quantitative determination of salbutamol in plasma, as either its trimethysilyl or t-butyldimethylsilyl ether, using a stable isotope multiple ion recording technique, Biomedical Mass Spectrometry, 6, pp. 184-190, (1976)
[18]  
McCarthy P.T., Atwal S., Sykes A.P., Ayres J.G., Measurement of terbutaline and salbutamol in plasma by high performance liquid chromatography with fluorescence detection, Biomedical Chromatography, 7, pp. 25-28, (1993)
[19]  
Meyer H.H.D., Rinke L., Dursch I., Residue screening for the β-agonists clenbuterol, salbutamol and cimaterol in urine enzyme immunoassay, and high-performance liquid chromatography, Journal of Chromatography, 564, pp. 551-556, (1991)
[20]  
Miller L.G., Greenblatt D.J., Determination of albuterol in human plasma by HPLC with fluorescence detection, Journal of Chromatography, 381, pp. 205-208, (1986)