TRANSARTICULAR (TRANSPEDICULAR) METAL PLATE FIXATION FOR STABILIZATION OF THE LUMBAR AND THORACIC SPINE

被引:10
作者
HERRMANN, HD
机构
[1] The Neurosurgical Clinic of the University of the Saarland, Homburg/Saar
关键词
D O I
10.1007/BF01406023
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The operation of metal plate fixation of the articular column with the screws traversing the anterior vertebral arch (ventral pedicles) and anchored within the vertebral body is described in detail. The method can be recommended as easy to perform. It gives sufficiently stable fixation in cases where instability of the thoracic or lumbar spine can be expected during an operation from the dorsal approach. Four cases are presented to illustrate the indications and method. © 1979 Springer-Verlag.
引用
收藏
页码:101 / 110
页数:10
相关论文
共 14 条
[11]  
ROYCAMILLE R, 1970, PRESSE MED, V78, P1447
[12]  
SCHLEGEL KF, 1974, Z ORTHOP GRENZGEB, V112, P766
[13]  
WEIGERT M, 1974, Z ORTHOP GRENZGEB, V112, P921
[14]  
WERLINICH M, 1974, INT SURG, V59, P269