COMPARISON OF 2 METHODS FOR ASSESSING PATIENT DOSE FROM COMPUTED-TOMOGRAPHY

被引:52
作者
GELEIJNS, J
VANUNNIK, JG
ZOETELIEF, J
ZWEERS, D
BROERSE, JJ
机构
[1] LEIDEN UNIV HOSP,DEPT DIAGNOST RADIOL,2300 RC LEIDEN,NETHERLANDS
[2] TNO,MED BIOL LAB,2280 HV RIJSWIJK,NETHERLANDS
[3] ONZE LIEVE VROUW HOSP,1091 HA AMSTERDAM,NETHERLANDS
关键词
D O I
10.1259/0007-1285-67-796-360
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Radiation exposure of the patient during routine computed tomography (CT) examinations is known to be relatively high. In this study organ doses were determined using two methods and these served as a basis to calculate the effective dose. Thermoluminescence dosemeters (TLDs) were used to measure organ doses in an anthropomorphic Rando Alderson phantom. In addition organ doses were obtained from measurement of the computed tomography dose index (CTDI) and the application of published organ dose conversion factors. Effective dose values obtained with the Rando phantom for CT head examinations are about 1-2 mSv. For CT examinations of thorax and abdomen the estimation of effective doses with the Rando phantom yielded values of 18 and 24 mSv respectively. Effective doses determined from CTDI values were similar for CT head examinations (1-2 mSv) but were smaller for the CT thorax scan (11-15 mSv) and the CT abdomen scan (15-20 mSv). In this study effective dose values are relatively high compared with the results of other investigators who indicate effective doses and effective dose equivalents of 7-9 mSv for CT of the thorax and of 4-16 mSv for CT of the abdomen. Discrepancies between our results and those from other studies could be attributed to differences in the selected CT protocols and to differences in the phantoms employed. Measurements in an anthropomorphic phantom were laborious and time-consuming. Assessment of organ doses from CTDI values and organ dose conversion factors will therefore be the preferable method for future dose intercomparisons at different locations in The Netherlands. It should be realized, however, that this method tends to yield up to 40% lower effective dose values compared with the assessment of effective dose with a Rando phantom.
引用
收藏
页码:360 / 365
页数:6
相关论文
共 12 条
  • [1] BABBEL R, 1991, AM J ROENTGENOL, V157, P1093
  • [2] HUDA W, 1984, HEALTH PHYS, V47, P463
  • [3] ICRP, 1977, ICRP PUBL, V26, P1383
  • [4] JONES DG, 1991, NRPBR250 NAT RAD PRO
  • [5] LOW-DOSE CT OF THE LUNGS - PRELIMINARY-OBSERVATIONS
    NAIDICH, DP
    MARSHALL, CH
    GRIBBIN, C
    ARAMS, RS
    MCCAULEY, DI
    [J]. RADIOLOGY, 1990, 175 (03) : 729 - 731
  • [6] DETERMINATIONS OF ORGAN DOSES AND EFFECTIVE DOSE EQUIVALENTS FROM COMPUTED TOMOGRAPHIC EXAMINATION
    NISHIZAWA, K
    MARUYAMA, T
    TAKAYAMA, M
    OKADA, M
    HACHIYA, J
    FURUYA, Y
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (757) : 20 - 28
  • [7] A METHOD FOR DESCRIBING THE DOSES DELIVERED BY TRANSMISSION-X-RAY COMPUTED-TOMOGRAPHY
    SHOPE, TB
    GAGNE, RM
    JOHNSON, GC
    [J]. MEDICAL PHYSICS, 1981, 8 (04) : 488 - 495
  • [8] THE TISSUE-EQUIVALENCE OF THE ALDERSON RANDO ANTHROPOMORPHIC PHANTOM FOR X-RAYS OF DIAGNOSTIC QUALITIES
    SHRIMPTON, PC
    WALL, BF
    FISHER, ES
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (01) : 133 - 139
  • [9] SHRIMPTON PC, 1991, NRPBR249 NAT RAD PRO
  • [10] ZANKL M, 1991, GSF3091 GES STRAHL U