REDUCTION OF PATIENT DOSES FROM BARIUM MEAL AND BARIUM ENEMA EXAMINATIONS THROUGH CHANGES IN EQUIPMENT FACTORS

被引:48
作者
MARTIN, CJ [1 ]
HUNTER, S [1 ]
机构
[1] UNIV ABERDEEN,ABERDEEN AB2 4NU,SCOTLAND
关键词
D O I
10.1259/0007-1285-67-804-1196
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A study of patient doses for barium meal and barium enema examinations has been made for X-ray departments throughout Grampian Region. Dose-area products are substantially less than UK reference levels. Contributions from fluoroscopy and radiography varied significantly between different units, with fluoroscopy making up 35-92% of the mean doses for barium meals and 24-57% for barium enemas, Equipment related factors had a greater influence on patient doses than radiologists' techniques. The gain of the image intensifier and the exposure factors selected by the automatic exposure control (AEC) were the most important factors determining doses for fluoroscopy. Changes in kV/mA factors selected by the AEC have allowed reductions of 20-50% to be made in effective dose from fluoroscopy with some units. The method used for recording images was the major influence on radiographic doses, Digital spot images or fluorographic films taken from the intensifier gave only 10-20% of the dose with a film/screen system and are recommended where the image quality is satisfactory for the application, Changes in film/screen systems have given worthwhile reductions in radiographic doses. If all factors are optimized, mean doses for barium examinations could be reduced to 20% of current reference levels.
引用
收藏
页码:1196 / 1205
页数:10
相关论文
共 17 条
[1]   RADIATION-DOSE RECEIVED BY PATIENTS DURING BARIUM MEAL INVESTIGATIONS UNDER AUTOMATIC BRIGHTNESS CONTROL [J].
FAULKNER, K ;
BRAMALL, G .
BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (685) :31-34
[2]   DEPENDENCE OF THE PHOTON BACKSCATTER FACTOR FOR WATER ON SOURCE-TO-PHANTOM DISTANCE AND IRRADIATION FIELD SIZE [J].
GROSSWENDT, B .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (09) :1233-1245
[3]  
HART D, 1994, NRPB R262 REP
[4]   AUDIT IN ACTION - SIGNIFICANT REDUCTION OF DOUBLE-CONTRAST BARIUM ENEMA SCREENING TIME WITH NO LOSS OF EXAMINATION QUALITY [J].
HORTON, D ;
COOK, AM ;
TAYLOR, AD .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (774) :507-509
[5]   EFFECTIVE DOSE EQUIVALENTS, HE, IN DIAGNOSTIC-RADIOLOGY [J].
HUDA, W ;
BISSESSUR, K .
MEDICAL PHYSICS, 1990, 17 (06) :998-1003
[6]  
JONES DG, 1985, NRPB R186 REP
[7]  
LEHERON JC, 1992, PHYS MED BIOL, V37, P2117, DOI 10.1088/0031-9155/37/11/008
[8]   IMPLEMENTATION OF A PROGRAM FOR REDUCTION OF RADIOGRAPHIC DOSES AND RESULTS ACHIEVED THROUGH INCREASES IN TUBE POTENTIAL [J].
MARTIN, CJ ;
DARRAGH, CL ;
MCKENZIE, GA ;
BAYLISS, AP .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (783) :228-233
[9]  
MARTIN CJ, BRIT J RADIOL, V67, P864
[10]   AN INVESTIGATION INTO THE LEVELS OF RADIATION EXPOSURE IN DIAGNOSTIC EXAMINATIONS INVOLVING FLUOROSCOPY [J].
ROWLEY, KA ;
HILL, SJ ;
WATKINS, RA ;
MOORES, BM .
BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (710) :167-173