ONLINE PORTAL IMAGING - IMAGE QUALITY DEFINING PARAMETERS FOR PELVIC FIELDS - A CLINICAL-EVALUATION

被引:18
作者
VERELLEN, D [1 ]
DENEVE, W [1 ]
VANDENHEUVEL, F [1 ]
COGHE, M [1 ]
LOUIS, O [1 ]
STORME, G [1 ]
机构
[1] FREE UNIV BRUSSELS,ACAD HOSP,DEPT RADIOL,B-1090 BRUSSELS,BELGIUM
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1993年 / 27卷 / 04期
关键词
ONLINE PORTAL IMAGING; PRECISION RADIOTHERAPY; IMAGE ENHANCEMENT; EVALUATING IMAGE QUALITY;
D O I
10.1016/0360-3016(93)90472-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A test of several image enhancement techniques, performed on on-line portal images in real clinical circumstances, is presented. In addition a score system enabling us to evaluate image quality on pelvic fields is proposed and validated. Methods and Materials: Localization images (n = 546) generated by an on-line portal imaging system during the treatment of 13 patients on pelvic fields were obtained by delivering a radiation dose of 6-8 cGy by an 18 MV photon beam, and recorded with a silicon intensified target video camera with adjustable gain, kV- and black level. Set-up errors were corrected before continuing irradiation. A scoring system based on the number of visible bone-soft tissue edges and transformed to a scale 0 to 5 was developed to judge image quality. A validation of this classification of images was performed with the use of transsectional bone-densities (bone-density *radiological path length) specified at the score defining landmarks. A high pass filter was used on all images, additional online open field subtraction was performed on 242 fields. Off-line study was performed in which a panel consisting of two groups (one composed of three radiation oncologists, the other of three radiotherapy technologists), scored 470 pelvic fields without further enhancement, and the same images with Contrast Limited Adaptive Histogram Equalization (CLAHE) (Pizer et al.). Two different clipping levels (3.0 and 5.0) were studied. Results: Gender and transsectional bone-densities were the most defining patient-related factors influencing image quality. Camera settings, gantry angle, and image post-processing were important non-patient-related factors. All investigators judged CLAHE to ameliorate low contrast images and to deteriorate good quality images (p < 0.001).
引用
收藏
页码:945 / 952
页数:8
相关论文
共 22 条
[1]   MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER [J].
BIJHOLD, J ;
LEBESQUE, JV ;
HART, AAM ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) :261-271
[2]   ROUTINE CLINICAL ONLINE PORTAL IMAGING FOLLOWED BY IMMEDIATE FIELD ADJUSTMENT USING A TELE-CONTROLLED PATIENT COUCH [J].
DENEVE, W ;
VANDENHEUVEL, F ;
DEBEUKELEER, M ;
COGHE, M ;
THON, L ;
DEROOVER, P ;
VANLANCKER, M ;
STORME, G .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (01) :45-54
[3]  
DENEVE W, 1992, INT J RADIAT ONCOL, V25, P517
[4]  
FERGUSON GA, 1983, STATISTICAL ANAL PSY
[5]   A METHOD TO ANALYZE 2-DIMENSIONAL DAILY RADIOTHERAPY PORTAL IMAGES FROM AN ONLINE FIBEROPTIC IMAGING-SYSTEM [J].
GRAHAM, ML ;
CHENG, AY ;
GEER, LY ;
BINNS, WR ;
VANNIER, MW ;
WONG, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (03) :613-619
[6]  
KALENDER WA, 1989, EUR J RADIOL, V9, P75
[7]   THE ENHANCEMENT OF RADIOTHERAPY VERIFICATION IMAGES BY AN AUTOMATED EDGE-DETECTION TECHNIQUE [J].
LESZCZYNSKI, KW ;
SHALEV, S ;
COSBY, NS .
MEDICAL PHYSICS, 1992, 19 (03) :611-621
[8]   DIGITAL CONTRAST ENHANCEMENT FOR ONLINE PORTAL IMAGING [J].
LESZCZYNSKI, KW ;
SHALEV, S .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1989, 27 (05) :507-512
[9]  
LESZCZYNSKI KW, 1990, SPIE P, V1231, P401
[10]   1ST CLINICAL-EXPERIENCE WITH A NEWLY DEVELOPED ELECTRONIC PORTAL IMAGING DEVICE [J].
MEERTENS, H ;
VANHERK, M ;
BIJHOLD, J ;
BARTELINK, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (05) :1173-1181