THE STABILITY OF 3 DIFFERENT CEMENTLESS TIBIAL COMPONENTS - A RANDOMIZED RADIOSTEREOMETRIC STUDY IN 45 KNEE ARTHROPLASTY PATIENTS

被引:37
作者
HILDING, MB [1 ]
YUAN, XH [1 ]
RYD, L [1 ]
机构
[1] UNIV LUND HOSP,S-22185 LUND,SWEDEN
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1995年 / 66卷 / 01期
基金
英国医学研究理事会;
关键词
D O I
10.3109/17453679508994633
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We conducted a prospective, randomized study of 45 patients to evaluate 3 different uncemented tibial component designs in total knee arthroplasty. The stability of the components was assessed by radiostereometry (RSA), both as migration during 2 years and as inducible displacement at 2 years. The PCA resurfacing, the Tricon stem and the Tricon-M prosthesis groups showed a similar level of migration at 2 years, about 1.4 mm. In response to externally applied rotatory forces, the Tricon groups rotated more than the PCA group, interpreted as a consequence of the more conforming articular surface in the Tricon design. The series was divided into one group of continuously migrating prostheses with a poor prognosis (unstable, one third) and another group of prostheses in which migration stopped after 1 year (stable, two thirds). With this classification, no differences between the prostheses design groups were revealed. However, the unstable group showed a larger inducible displacement by provocation, an association hitherto not established.
引用
收藏
页码:21 / 27
页数:7
相关论文
共 26 条
[1]  
Ahlb_ack S., 1968, ACTA RADIOL DIAGN, P7, DOI [10.1148/23.1.134, DOI 10.1148/23.1.134]
[2]  
ALBREKTSSON BEJ, 1991, THESIS GOTHENBURG U
[3]   THE FIXATION OF A PROXIMAL TIBIAL POLYETHYLENE PROSTHESIS WITHOUT CEMENT [J].
BLAHA, JD ;
INSLER, HP ;
FREEMAN, MAR ;
REVELL, PA ;
TODD, RC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1982, 64 (03) :326-335
[4]  
BURKE DW, 1991, 37TH P ANN ORS M AN
[5]   POLYETHYLENE WEAR OF METAL-BACKED TIBIAL COMPONENTS IN TOTAL AND UNICOMPARTMENTAL KNEE PROSTHESES [J].
ENGH, GA ;
DWYER, KA ;
HANES, CK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01) :9-17
[6]   EARLY MIGRATION AND LATE ASEPTIC FAILURE OF PROXIMAL FEMORAL PROSTHESES [J].
FREEMAN, MAR ;
PLANTEBORDENEUVE, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (03) :432-438
[7]  
GIORI NJ, 1995, IN PRESS J ARTHROPLA
[8]  
HILDING M, 1993, AM J KNEE SURG, V6, P150
[9]   FAILED INNOVATION IN TOTAL HIP-REPLACEMENT - DIAGNOSIS AND PROPOSALS FOR A CURE [J].
HUISKES, R .
ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (06) :699-716
[10]   COMPARISON OF 4 MODELS OF TOTAL KNEE-REPLACEMENT PROSTHESES [J].
INSALL, JN ;
RANAWAT, CS ;
AGLIETTI, P ;
SHINE, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (06) :754-765