MEASUREMENT OF RAT-BRAIN PERFUSION BY NMR USING SPIN LABELING OF ARTERIAL WATER - INVIVO DETERMINATION OF THE DEGREE OF SPIN LABELING

被引:100
作者
ZHANG, WG
WILLIAMS, DS
KORETSKY, AP
机构
[1] CARNEGIE MELLON UNIV,DEPT BIOL SCI,4400 5TH AVE,PITTSBURGH,PA 15213
[2] NMR CTR BIOMED RES,PITTSBURGH,PA
关键词
CEREBRAL BLOOD FLOW; H-1; NMR; STEAM; ADIABATIC FAST PASSAGE;
D O I
10.1002/mrm.1910290323
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In vivo NMR experiments are performed to determine the degree of spin labeling for measurement of tissue perfusion by NMR using spin labeling of arterial water by adiabatic fast passage. Arterial water spins are labeled using flow in the presence of a field gradient and B1 irradiation to fulfill the conditions for adiabatic fast passage spin inversion. It is demonstrated that the NMR‐measured tissue perfusion is not affected by changing the degree of spin labeling as long as the degree of spin labeling is determined and accounted for according to the model used for calculating perfusion. By measuring the degree of spin labeling with different arterial blood flow velocities induced by different arterial pCO2, it is also demonstrated that, when spin labeling is carried out by adiabatic fast passage, the degree of spin labeling is not affected by changes in arterial blood flow velocity over a broad range. Copyright © 1993 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:416 / 421
页数:6
相关论文
共 7 条
[1]   PERFUSION IMAGING [J].
DETRE, JA ;
LEIGH, JS ;
WILLIAMS, DS ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :37-45
[2]   PROJECTION ANGIOGRAMS OF BLOOD LABELED BY ADIABATIC FAST PASSAGE [J].
DIXON, WT ;
DU, LN ;
FAUL, DD ;
GADO, M ;
ROSSNICK, S .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (03) :454-462
[3]   QUANTITATIVE H-1 MAGNETIZATION TRANSFER IMAGING INVIVO [J].
ENG, J ;
CECKLER, TL ;
BALABAN, RS .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :304-314
[4]   LOCALIZED PROTON SPECTROSCOPY USING STIMULATED ECHOES [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
JOURNAL OF MAGNETIC RESONANCE, 1987, 72 (03) :502-508
[5]   MR IMAGING OF VENOUS AND ARTERIAL FLOW BY A SELECTIVE SATURATION-RECOVERY SPIN-ECHO (SSRSE) METHOD [J].
WEHRLI, FW ;
SHIMAKAWA, A ;
MACFALL, JR ;
AXEL, L ;
PERMAN, W .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (03) :537-545
[6]   MAGNETIC-RESONANCE-IMAGING OF PERFUSION USING SPIN INVERSION OF ARTERIAL WATER [J].
WILLIAMS, DS ;
DETRE, JA ;
LEIGH, JS ;
KORETSKY, AP .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (01) :212-216
[7]   MEASUREMENT OF BRAIN PERFUSION BY VOLUME-LOCALIZED NMR-SPECTROSCOPY USING INVERSION OF ARTERIAL WATER SPINS - ACCOUNTING FOR TRANSIT-TIME AND CROSS-RELAXATION [J].
ZHANG, WG ;
WILLIAMS, DS ;
DETRE, JA ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) :362-371