CHLOROACETONITRILE AS ELUENT ADDITIVE IN THERMOSPRAY LIQUID-CHROMATOGRAPHY NEGATIVE-ION MASS-SPECTROMETRY FOR THE CHARACTERIZATION OF CHLORINATED ORGANIC POLLUTANTS

被引:25
作者
VREEKEN, RJ [1 ]
BRINKMAN, UAT [1 ]
DEJONG, GJ [1 ]
BARCELO, D [1 ]
机构
[1] CSIC,CID,DEPT ENVIRONM CHEM,E-08034 BARCELONA,SPAIN
来源
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY | 1990年 / 19卷 / 08期
关键词
D O I
10.1002/bms.1200190806
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The use of chloroacetonitrile as eluent additive in thermospray liquid chromatography/mass spectrometry in the negative ion mode using filament‐off, filament‐on and discharge ionization modes has been studied with chlorophenols and chlorinated phenoxy acids as test compounds. In the absence of chloroacetonitrile from the eluent, different base peaks were observed corresponding to [ M  H]−, [ M + H]− and [ M + CH3COOO]−, while in the presence of 2% chloroacetonitrile [M + Cl] − was the base peak in most cases when using the filament‐on and discharge ionization modes and had a maximum value of 30% relative abundance in the filament‐off mode. Most chloride attachment ([ M + Cl] − ion) was always observed in the filament‐on mode. Other ions observed were adduct ions with the ionizing additive (ammonium acetate) such as [M + CH3COO]− and [ M + (CH3COOH). (CH3COO)]− when the eluent contained no chloroacetonitrile and [ M + (CH3COOH). Cl]− when 2% chloroacetonitrile was present. The use of chloroacetonitrile in the eluent provides additional structural information in thermospray liquid chromatography/negative ion mass spectrometry. It does not cause any appreciable loss in sensitivity during flow injection or chromatographic analysis. Copyright © 1990 John Wiley & Sons, Ltd.
引用
收藏
页码:481 / 492
页数:12
相关论文
共 28 条
[21]   REPELLER EFFECTS IN DISCHARGE IONIZATION IN COMBINED LIQUID OR SUPERCRITICAL-FLUID CHROMATOGRAPHY-MASS SPECTROMETRY USING A THERMOSPRAY INTERFACE .1. CHANGES IN THE REAGENT GAS SPECTRUM [J].
NIESSEN, WMA ;
VANDERHOEVEN, RAM ;
DEKRAA, MAG ;
HEEREMANS, CEM ;
TJADEN, UR ;
VANDERGREEF, J .
JOURNAL OF CHROMATOGRAPHY, 1989, 474 (01) :113-122
[22]   EVALUATION OF MNDO CALCULATED PROTON AFFINITIES [J].
OLIVELLA, S ;
URPI, F ;
VILARRASA, J .
JOURNAL OF COMPUTATIONAL CHEMISTRY, 1984, 5 (03) :230-236
[23]   LIQUID CHROMATOGRAPHY-CHLORIDE-ATTACHMENT NEGATIVE CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
PARKER, CE ;
YAMAGUCHI, K ;
HARVAN, DJ ;
SMITH, RW ;
HASS, JR .
JOURNAL OF CHROMATOGRAPHY, 1985, 319 (03) :273-283
[24]   THE FRAGMENTATION OF NEGATIVE-IONS GENERATED BY ELECTRON-CAPTURE NEGATIVE-ION MASS-SPECTROMETRY - A REVIEW WITH NEW DATA [J].
STEMMLER, EA ;
HITES, RA .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 17 (04) :311-328
[25]   ANALYSIS OF SELECTED PESTICIDES BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY [J].
VOYKSNER, RD ;
BURSEY, JT ;
PELLIZZARI, ED .
JOURNAL OF CHROMATOGRAPHY, 1984, 312 (NOV) :221-235
[26]   OPTIMIZATION AND APPLICATION OF THERMOSPRAY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
VOYKSNER, RD ;
HANEY, CA .
ANALYTICAL CHEMISTRY, 1985, 57 (06) :991-996
[27]  
VOYKSNER RD, 1987, APPLICATIONS NEW MAS, pCH11
[28]  
WEAST RC, 1986, HDB CHEM PHYSICS