35-MM FILM SCANNER AS AN INTRAORAL DENTAL RADIOGRAPH DIGITIZER .1. A QUANTITATIVE-EVALUATION

被引:28
作者
SHROUT, MK
POTTER, BJ
YURGALAVAGE, HM
HILDEBOLT, CF
VANNIER, MW
机构
[1] EDWARD MALLINCKRODT INST RADIOL, ST LOUIS, MO 63110 USA
[2] WASHINGTON UNIV, SCH MED, ST LOUIS, MO 63110 USA
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 1993年 / 76卷 / 04期
关键词
D O I
10.1016/0030-4220(93)90020-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A 35-mm slide scanner digital imaging system was tested for its suitability in digitizing intraoral dental radiographic film for quantitative studies. The system (Nikon model LS-3510AF Nikon Electronic Imaging, Nikon, Inc., Melville, N.Y.) uses a charge-coupled device linear photodiode array. The data content in the original film images was evaluated, and the system performance assessed objectively with the use of specially designed test films. Radiometric and geometric performances for the digitizing system were extracted from measurements and observations, and these were compared with published data for two other film digitizing systems (video camera DAGE MTI, Michigan City, Ind. and Barneyscan 35-mm film digitizer Barneyscan, Berkeley, Calif.). The techniques used to evaluate this system are easy and suitable for evaluation of any digitizing system. This scanner system (Nikon) was superior to previously evaluated systems in transforming and recording radiographic film densities across the range (0.3 to 2.0 optical density units) of clinically relevant optical densities. The scanner offers substantial advantage over the other digitizing systems for gray scale information from clinically important optical densities.
引用
收藏
页码:502 / 509
页数:8
相关论文
共 20 条
[1]   COMPUTER-ASSISTED DENSITOMETRIC IMAGE-ANALYSIS IN PERIODONTAL RADIOGRAPHY - A METHODOLOGICAL STUDY [J].
BRAGGER, D ;
PASQUALI, L ;
RYLANDER, H ;
CARNES, D ;
KORNMAN, KS .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (01) :27-37
[2]   COMPUTER-ASSISTED DENSITOMETRIC IMAGE-ANALYSIS (CADIA) FOR THE ASSESSMENT OF ALVEOLAR BONE-DENSITY CHANGES IN FURCATIONS [J].
BRAGGER, U ;
PASQUALI, L ;
WEBER, H ;
KORNMAN, KS .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1989, 16 (01) :46-52
[3]   A PRACTICAL METHOD TO MEASURE THE MTF OF CT SCANNERS [J].
DROEGE, RT ;
MORIN, RL .
MEDICAL PHYSICS, 1982, 9 (05) :758-759
[4]   A PRACTICAL METHOD TO ROUTINELY MONITOR RESOLUTION IN DIGITAL IMAGES [J].
DROEGE, RT .
MEDICAL PHYSICS, 1983, 10 (03) :337-343
[5]   AN EXPERIMENTAL-STUDY OF NEW DIAGNOSTIC METHODS FOR THE EXAMINATION OF OSSEOUS LESIONS IN THE TEMPOROMANDIBULAR-JOINT [J].
ENGELKE, W ;
RUTTIMANN, UE ;
TSUCHIMOCHI, M ;
BACHER, JD .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1992, 73 (03) :348-359
[6]   DIGITAL IMAGE-PROCESSING OF PERIAPICAL RADIOGRAPHS [J].
FUJITA, M ;
KODERA, Y ;
OGAWA, M ;
WADA, T ;
DOI, K .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1988, 65 (04) :490-494
[7]  
GOAZ PW, 1987, ORAL RADIOLOGY PRINC, P103
[8]   DETECTABILITY OF ARTIFICIAL MARGINAL BONE-LESIONS AS A FUNCTION OF LESION DEPTH - A COMPARISON BETWEEN SUBTRACTION RADIOGRAPHY AND CONVENTIONAL RADIOGRAPHIC TECHNIQUE [J].
GRONDAHL, K ;
KULLENDORFF, B ;
STRID, KG ;
GRONDAHL, HG ;
HENRIKSON, CO .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (03) :156-162
[9]  
Hausmann E, 1985, J Periodontol, V56 Suppl 11S, P4, DOI 10.1902/jop.1985.56.11s.4
[10]   QUANTITATIVE-EVALUATION OF DIGITAL DENTAL RADIOGRAPH IMAGING-SYSTEMS [J].
HILDEBOLT, CF ;
VANNIER, MW ;
PILGRAM, TK ;
SHROUT, MK .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1990, 70 (05) :661-668