DESIGN AND PERFORMANCE OF A FOCUSED BEAM LINE FOR SURFACE X-RAY-DIFFRACTION

被引:29
作者
NORRIS, C
FINNEY, MS
CLARK, GF
BAKER, G
MOORE, PR
VANSILFHOUT, R
机构
[1] SERC,DARESBURY LAB,WARRINGTON WA4 4AD,CHESHIRE,ENGLAND
[2] FOM,1098 SJ AMSTERDAM,NETHERLANDS
关键词
D O I
10.1063/1.1143207
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Focusing optics have been installed on the 5.0 T Wiggler beam line of the SRS at Daresbury Laboratory for use with x-ray diffraction measurements of surfaces and interfaces. A significant increase in the flux has been achieved without excessive degradation of the resolution in the vertical plane. The full width at half-maximum of the focused image compares well with the predictions of ray tracing analysis.
引用
收藏
页码:1083 / 1086
页数:4
相关论文
共 5 条
[1]   X-RAY MIRROR REFLECTIVITIES FROM 3.8 TO 50 KEV (3.3 TO 0.25 A) .2. PT, SI AND OTHER MATERIALS [J].
BILDERBACK, DH ;
HUBBARD, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 195 (1-2) :91-95
[2]  
BRAMMER RC, 1987, G8733 DAR LAB TECHN
[3]   MEDIUM POWER X-RAY CRYSTAL OPTICS FOR SYNCHROTRON RADIATION SOURCES [J].
CERNIK, R ;
HART, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 281 (02) :403-405
[4]  
HEALD SM, 1982, NUCL INSTRUM METHODS, V195, P59, DOI 10.1016/0029-554X(82)90757-1
[5]  
NORRIS C, 19867 DAR ANN REP, P124