POTENTIOMETRIC ION-SELECTIVE AND BIOSELECTIVE ELECTRODES BASED ON ASYMMETRIC POLYURETHANE MEMBRANES

被引:56
作者
LIU, D
MEYERHOFF, ME
GOLDBERG, HD
BROWN, RB
机构
[1] UNIV MICHIGAN,DEPT CHEM,ANN ARBOR,MI 48109
[2] UNIV MICHIGAN,DEPT ELECT ENGN & COMP SCI,ANN ARBOR,MI 48109
基金
美国国家科学基金会;
关键词
BIOSENSORS; ION-SELECTIVE ELECTRODES; POTENTIOMETRY; ASYMMETRIC MEMBRANES; POLYURETHANE MEMBRANES; SOLID-STATE ELECTRODES;
D O I
10.1016/0003-2670(93)80602-H
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The potentiometric ion responses of ammonium- and proton-selective electrodes prepared by incorporating appropriate neutral carriers within novel asymmetric polyurethane membranes are reported. The membranes are formed by first casting a plasticized polyurethane(PU)/terpoly(vinyl chloride/vinyl acetate/vinyl alcohol) (PVA)-based ion-selective membrane and then applying a thin second layer of a more hydrophilic polyurethane (HPU) containing polylysine. The resulting asymmetric membranes function equivalently to normal PU/PVA membranes and conventional poly(vinyl chloride) type membranes in terms of potentiometric ion selectivity and dynamic response properties. The large amount of amine functional groups from the polylysine within the outer hydrophilic layer can be further activated for direct enzyme immobilization. As examples, adenosine deaminase and urease are immobilized on ammonium- and proton-selective membranes, respectively, to yield adenosine and urea electrodes with good dynamic responses and sensitivities. Advantageous use of this new membrane system for preparation of solid-state microfabricated enzyme-based sensors is also described.
引用
收藏
页码:37 / 46
页数:10
相关论文
共 30 条
  • [1] ENZYME SENSORS BASED ON COATED-WIRE ELECTRODE - USE OF CARBOXYL-SUBSTITUTED POLYVINYL-CHLORIDE) AS A SUPPORT FOR IMMOBILIZING PENICILLINASE
    ANZAI, J
    SHIMADA, M
    OSA, T
    CHEN, C
    [J]. BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1987, 60 (11) : 4133 - 4137
  • [2] RECENT ADVANCES IN THE DEVELOPMENT AND ANALYTICAL APPLICATIONS OF BIOSENSING PROBES
    ARNOLD, MA
    MEYERHOFF, ME
    [J]. CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1988, 20 (03): : 149 - 196
  • [3] CARR PW, 1980, IMMOBILIZED ENZYMES, pCH5
  • [4] ENZYME ELECTRODE-BASED DIFFERENTIAL POTENTIOMETRIC CELL WITH ENHANCED SUBSTRATE SENSITIVITY
    CHA, GS
    MEYERHOFF, ME
    [J]. ELECTROANALYSIS, 1989, 1 (03) : 205 - 211
  • [5] ELECTROCHEMICAL PERFORMANCE, BIOCOMPATIBILITY, AND ADHESION OF NEW POLYMER MATRICES FOR SOLID-STATE ION SENSORS
    CHA, GS
    LIU, D
    MEYERHOFF, ME
    CANTOR, HC
    MIDGLEY, AR
    GOLDBERG, HD
    BROWN, RB
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (17) : 1666 - 1672
  • [6] POTENTIOMETRIC ION-SELECTIVE AND BIO-SELECTIVE ELECTRODES BASED ON ASYMMETRIC CELLULOSE-ACETATE MEMBRANES
    CHA, GS
    MEYERHOFF, ME
    [J]. TALANTA, 1989, 36 (1-2) : 271 - 278
  • [7] CUATRECASAS P, 1970, J BIOL CHEM, V245, P3059
  • [8] MICRO-ENZYME FIELD-EFFECT TRANSISTOR SENSOR USING DIRECT COVALENT BONDING OF UREASE
    GARDIES, F
    JAFFREZICRENAULT, N
    MARTELET, C
    PERROT, H
    VALLETON, JM
    ALEGRET, S
    [J]. ANALYTICA CHIMICA ACTA, 1990, 231 (02) : 305 - 308
  • [9] MICRO-FET BIOSENSORS USING POLYVINYLBUTYRAL MEMBRANE
    GOTOH, M
    TAMIYA, E
    KARUBE, I
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1989, 41 : 291 - 303
  • [10] GUILBAUL.GG, 1973, ANAL CHEM, V45, P417