CAUSE OF SIGNAL LOSS IN MR IMAGES OF OLD HEMORRHAGIC LESIONS

被引:35
作者
HARDY, PA
KUCHARCZYK, W
HENKELMAN, RM
机构
[1] UNIV TORONTO,DEPT MED BIOPHYS,TORONTO M4X 1K9,ONTARIO,CANADA
[2] UNIV TORONTO,TORONTO GEN HOSP,DEPT RADIOL,TORONTO M5S 1A1,ONTARIO,CANADA
关键词
Brain; hemorrhage; 10.7; MR studies; 10.1214; Hemorrhage; Magnetic resonance (MR); technology;
D O I
10.1148/radiology.174.2.2296664
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Old hemorrhagic lesions in the brain are characteristically surrounded by a band of hemosiderin-containing tissue. This region is typically of low signal intensity on long-echo-time (TE) radio-frequency (RF) spin-echo magnetic resonance (MR) images and on gradient-echo MR images. To determine the cause of signal loss in this band, the authors measured the signal that arises from imaging such a region with use of an RF spin-echo technique with a 180° pulse incrementally displaced from TE/2. The incremental loss of signal was small. Using an agar phantom containing iron particles, the authors also showed that signal loss results primarily from diffusion in magnetic gradients. They conclude that most signal loss in the dark band surrounding areas of late-stage hemorrhage arises from diffusion in areas of magnetic inhomogeneity.
引用
收藏
页码:549 / 555
页数:7
相关论文
共 31 条
[11]  
HAYMAN LA, 1989, AM J NEURORADIOL, V10, P681
[12]   RELAXOMETRY OF FERRITIN SOLUTIONS AND THE INFLUENCE OF THE FE-3+ CORE IONS [J].
KOENIG, SH ;
BROWN, RD ;
GIBSON, JF ;
WARD, RJ ;
PETERS, TJ .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) :755-767
[13]  
KOMIYAMA M, 1988, AM J NEURORADIOL, V9, P261
[14]   MR IMAGING OF INTRAVOXEL INCOHERENT MOTIONS - APPLICATION TO DIFFUSION AND PERFUSION IN NEUROLOGIC DISORDERS [J].
LEBIHAN, D ;
BRETON, E ;
LALLEMAND, D ;
GRENIER, P ;
CABANIS, E ;
LAVALJEANTET, M .
RADIOLOGY, 1986, 161 (02) :401-407
[15]  
Ludeke K M, 1985, Magn Reson Imaging, V3, P329, DOI 10.1016/0730-725X(85)90397-2
[16]   STUDIES OF DIFFUSION IN RANDOM-FIELDS PRODUCED BY VARIATIONS IN SUSCEPTIBILITY [J].
MAJUMDAR, S ;
GORE, JC .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (01) :41-55
[17]   THE INFLUENCE OF PULSE SEQUENCE ON THE RELAXATION EFFECTS OF SUPERPARAMAGNETIC IRON-OXIDE CONTRAST AGENTS [J].
MAJUMDAR, S ;
ZOGHBI, SS ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1989, 10 (03) :289-301
[18]   PHASE AND SENSITIVITY OF RECEIVER COILS IN MAGNETIC-RESONANCE-IMAGING [J].
MCVEIGH, ER ;
BRONSKILL, MJ ;
HENKELMAN, RM .
MEDICAL PHYSICS, 1986, 13 (06) :806-814
[19]  
NORFRAY JF, 1988, AM J NEURORADIOL, V9, P77
[20]   NUCLEAR MAGNETIC-RESONANCE (NMR) IMAGING OF INTRACEREBRAL HEMORRHAGE IN THE ACUTE AND RESOLVING PHASES [J].
SIPPONEN, JT ;
SEPPONEN, RE ;
SIVULA, A .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (06) :954-959