IN-VITRO EVALUATION OF 3-DIMENSIONAL ULTRASONOGRAPHY IN VOLUME ESTIMATION OF ABDOMINAL ORGANS

被引:102
作者
GILJA, OH [1 ]
THUNE, N [1 ]
MATRE, K [1 ]
HAUSKEN, T [1 ]
ODEGAARD, S [1 ]
BERSTAD, A [1 ]
机构
[1] CHRISTIAN MICHELSEN RES, BERGEN, NORWAY
关键词
ABDOMINAL ORGANS; KIDNEY; STOMACH; 3-DIMENSIONAL RECONSTRUCTION; VOLUME MEASUREMENTS; ULTRASONIC IMAGING; ULTRASONOGRAPHY;
D O I
10.1016/0301-5629(94)90080-9
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of this study was to evaluate the accuracy and precision of a three-dimensional (3D) ultrasound system in volume estimation of abdominal organs in vitro. A mechanical sector scanner coupled to a stepping motor recorded images of porcine stomach and kidneys. The transducer was tilted through 88-degrees yielding 81 frames, and volume estimation was performed digitally after interactive manual contour indication and organ reconstruction in 3 dimensions. This 3D system showed good correlation (r = 0.998) between estimated and true volumes. Volume estimation of stomach and kidneys using 3.25 MHz probe demonstrated limits of agreement of 0.877 to 1.146 and 1.007 to 1.125, respectively, depicting estimated volumes as a proportion of true volumes in 95% of the examinations. Intra- and interobserver variation of the tracing procedure revealed low values. We conclude that this 3D ultrasound system performs high accuracy and precision in volume estimation.
引用
收藏
页码:157 / 165
页数:9
相关论文
共 18 条
  • [1] [Anonymous], 1991, GRAPHICS GEMS
  • [2] EVALUATION OF A 3-DIMENSIONAL RECONSTRUCTION TO COMPUTE LEFT-VENTRICULAR VOLUME AND MASS
    ARIET, M
    GEISER, EA
    LUPKIEWICZ, SM
    CONETTA, DA
    CONTI, CR
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (03) : 415 - 420
  • [3] VOLUME MEASUREMENT BY ULTRASONIC TRANSVERSE OR SAGITTAL CROSS-SECTIONAL SCANNING
    BASSET, O
    GIMENEZ, G
    MESTAS, JL
    CATHIGNOL, D
    DEVONEC, M
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (03) : 291 - 296
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] STATISTICAL-METHODS FOR ASSESSING OBSERVER VARIABILITY IN CLINICAL MEASURES
    BRENNAN, P
    SILMAN, A
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 1992, 304 (6840): : 1491 - 1494
  • [6] INVITRO EVALUATION OF AN ULTRASONIC 3-DIMENSIONAL IMAGING AND VOLUME SYSTEM
    BRINKLEY, JF
    MURAMATSU, SK
    MCCALLUM, WD
    POPP, RL
    [J]. ULTRASONIC IMAGING, 1982, 4 (02) : 126 - 139
  • [7] 3-DIMENSIONAL (3D) ULTRASOUND IMAGING OF THE GALLBLADDER AND DILATED BILIARY TREE - RECONSTRUCTION FROM REAL-TIME B-SCANS
    FINE, D
    PERRING, S
    HERBETKO, J
    HACKING, CN
    FLEMING, JS
    DEWBURY, KC
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (767) : 1056 - 1057
  • [8] GANAPATHY S, 1982, COMPUT GRAPHICS ACM, V16, P69, DOI DOI 10.1145/965145.801264
  • [9] Gopal A S, 1992, J Am Soc Echocardiogr, V5, P115
  • [10] ACCURACY AND REPEATABILITY OF BLADDER VOLUME MEASUREMENT USING ULTRASONIC-IMAGING
    GRIFFITHS, CJ
    MURRAY, A
    RAMSDEN, PD
    [J]. JOURNAL OF UROLOGY, 1986, 136 (04) : 808 - 812