A METHOD FOR HIGH-PERFORMANCE SEQUENCE-ANALYSIS USING POLYVINYLIDENE DIFLUORIDE MEMBRANES WITH A BIPHASIC REACTION COLUMN SEQUENCER

被引:9
作者
REIM, DF [1 ]
SPEICHER, DW [1 ]
机构
[1] WISTAR INST ANAT & BIOL,PHILADELPHIA,PA 19104
关键词
D O I
10.1006/abio.1994.1027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Methods have been developed for high-sensitivity sequence analysis of proteins electroblotted onto polyvinylidene difluoride (PVDF) membranes using a Hewlett-Packard G1005A protein sequencer. This sequencer normally uses a biphasic (hydrophobic/hydrophilic) reaction column which was designed to accommodate loading and cleanup of samples from diverse solutions. However, the standard column, programs, and chemistry were not designed to accommodate PVDF, which has become a common sequencing support. In this study, a systematic evaluation of the suitability of this sequencer for analysis using PVDF bound samples was performed and included evaluation of: different wash and extraction solvents, multiple programming changes, two alternative formulations of coupling reagents, and the effect of direction for solvent and reagent deliveries. High-performance analysis of PVDF bound samples was achieved by: using a modified reaction column with an empty hydrophobic (top) half of the column module, program modifications for the reaction column and converter, substitution of ethyl acetate for the standard S2/3 extraction solvent and using prototype Version 2.0 formulations of the coupling reagents, R1 and R2. High-performance sequence analyses of experimental samples electroblotted from either 1D or 2D gels onto high-retention PVDF membranes were obtained with a 41-min cycle time, including experimental samples with initial coupling yields <2 pmol. Routine sequencer performance was comparable to, or slightly better than, a conventional gas-phase sequencer which had been previously optimized by us for high-performance sequence analysis of electroblotted samples in the low pmol range. © 1994 Academic Press. All rights reserved.
引用
收藏
页码:213 / 222
页数:10
相关论文
共 15 条
[1]  
CRIMMINS DL, 1992, TECHNIQUES PROTEIN C, V3, P35
[2]   A PROTEIN SEQUENATOR [J].
EDMAN, P ;
BEGG, G .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1967, 1 (01) :80-&
[3]   INTERNAL PROTEIN-SEQUENCE ANALYSIS - ENZYMATIC DIGESTION FOR LESS THAN 10 MU-G OF PROTEIN-BOUND TO POLYVINYLIDENE DIFLUORIDE OR NITROCELLULOSE MEMBRANES [J].
FERNANDEZ, J ;
DEMOTT, M ;
ATHERTON, D ;
MISCHE, SM .
ANALYTICAL BIOCHEMISTRY, 1992, 201 (02) :255-264
[4]   CLEAVAGE OF STRUCTURAL PROTEINS DURING ASSEMBLY OF HEAD OF BACTERIOPHAGE-T4 [J].
LAEMMLI, UK .
NATURE, 1970, 227 (5259) :680-+
[5]  
MATSUDAIRA P, 1987, J BIOL CHEM, V262, P10035
[6]   MICROSEQUENCE ANALYSIS OF ELECTROBLOTTED PROTEINS .1. COMPARISON OF ELECTROBLOTTING RECOVERIES USING DIFFERENT TYPES OF PVDF MEMBRANES [J].
MOZDZANOWSKI, J ;
SPEICHER, DW .
ANALYTICAL BIOCHEMISTRY, 1992, 207 (01) :11-18
[7]   HIGH-SENSITIVITY GAS-PHASE SEQUENCE-ANALYSIS OF PROTEINS AND PEPTIDES ON PVDF MEMBRANES USING SHORT CYCLE TIMES [J].
REIM, DF ;
SPEICHER, DW .
ANALYTICAL BIOCHEMISTRY, 1993, 214 (01) :87-95
[8]   MICROSEQUENCE ANALYSIS OF ELECTROBLOTTED PROTEINS .2. COMPARISON OF SEQUENCE PERFORMANCE ON DIFFERENT TYPES OF PVDF MEMBRANES [J].
REIM, DF ;
SPEICHER, DW .
ANALYTICAL BIOCHEMISTRY, 1992, 207 (01) :19-23
[9]  
REIM DF, 1992, TECHNIQUES PROTEIN C, V3, P53
[10]   MICROSEQUENCE ANALYSIS OF PEPTIDES AND PROTEINS .6. A CONTINUOUS-FLOW REACTOR FOR SAMPLE CONCENTRATION AND SEQUENCE-ANALYSIS [J].
SHIVELY, JE ;
MILLER, P ;
RONK, M .
ANALYTICAL BIOCHEMISTRY, 1987, 163 (02) :517-529