RELIABILITY OF B-MODE ULTRASOUND FOR THE MEASUREMENT OF BODY-FAT AND MUSCLE THICKNESS

被引:48
作者
ISHIDA, Y
CARROLL, JF
POLLOCK, ML
GRAVES, JE
LEGGETT, SH
机构
[1] UNIV FLORIDA,CTR EXERCISE SCI,COLL MED,GAINESVILLE,FL 32611
[2] UNIV FLORIDA,CTR EXERCISE SCI,COLL HLTH & HUMAN PERFORMANCE,GAINESVILLE,FL 32611
关键词
D O I
10.1002/ajhb.1310040410
中图分类号
Q98 [人类学];
学科分类号
030303 [人类学];
摘要
B-mode ultrasound was used to measure fat and muscle thicknesses on 30 subjects (17 men, 13 women, age = 20-37 yr) at 14 sites (triceps, biceps, forearm, chest [males only], subscapular, axilla, abdomen, suprailium, lumbar, quadriceps, suprapatellar, hamstrings, medial calf, and posterior calf) on two different days. Quadruplicate photographic images (trials) were printed from a single measurement at each site on each day. Two investigators each measured two of the images from each site. Each thickness was measured to the nearest 0.05 mm with a vernier caliper. Generalizability theory was used to determine the relative contribution of subjects, investigators, days, and trials to the total measurement variability. Subjects accounted for 84-96% of the variance in the muscle measurements and for 79-97% of the variance in the fat measurements. A subjects-by-day interaction accounted for 2-13% of the variance in muscle measurements and 2-12% of the variance in fat measurements. The contribution by investigators and trials to the variance was less than 1%. Generalizability coefficients (G) exceeding 0.92 were obtained for all sites for muscle measurements, while G for fat measurements exceeded 0.90 for all but the axilla site (G = 0.88). These results indicate that B-mode ultrasound is a highly reliable method for the measurement of both fat and muscle thicknesses in young males and females.
引用
收藏
页码:511 / 520
页数:10
相关论文
共 25 条
[1]
BALTA PJ, 1981, LANCET, V1, P504
[2]
COMPARISON OF ULTRASOUND AND SKINFOLD MEASUREMENTS IN ASSESSMENT OF SUBCUTANEOUS AND TOTAL FATNESS [J].
BORKAN, GA ;
HULTS, DE ;
CARDARELLI, J ;
BURROWS, BA .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1982, 58 (03) :307-313
[3]
BULLEN BA, 1965, HUM BIOL, V37, P375
[4]
ULTRASONIC AND SKINFOLD CALIPER MEASURES OF SUBCUTANEOUS ADIPOSE-TISSUE THICKNESS IN ELDERLY MEN AND WOMEN [J].
CHUMLEA, WC ;
ROCHE, AF .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1986, 71 (03) :351-357
[5]
ULTRASOUND AS AN APPROACH TO ASSESSING BODY-COMPOSITION [J].
FANELLI, MT ;
KUCZMARSKI, RJ .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1984, 39 (05) :703-709
[6]
FUKUNAGA T, 1989, JAP J MED ULTRASONIC, V16, P50
[7]
GLEIM GW, 1979, MED SCI SPORT EXER, V11, P102
[8]
Harrison G, 1988, ANTHROPOMETRIC STAND, P55
[9]
HAWES SF, 1972, P NUTR SOC, V31, pA91
[10]
VALIDITY OF ULTRASONIC TECHNIQUE AS A METHOD OF MEASURING SUBCUTANEOUS ADIPOSE-TISSUE [J].
HAYMES, EM ;
LUNDEGREN, HM ;
LOOMIS, JL ;
BUSKIRK, ER .
ANNALS OF HUMAN BIOLOGY, 1976, 3 (03) :245-251