OCCUPATIONAL EXPOSURE IN PEDIATRIC CARDIAC-CATHETERIZATION

被引:23
作者
LI, LB [1 ]
KAI, M [1 ]
TAKANO, K [1 ]
IKEDA, S [1 ]
MATSUURA, M [1 ]
KUSAMA, T [1 ]
机构
[1] NIHON UNIV, ITABASHI HOSP, DEPT RADIOL TECHNOL, ITABASHI KU, TOKYO 173, JAPAN
来源
HEALTH PHYSICS | 1995年 / 69卷 / 02期
关键词
THERMOLUMINESCENCE DOSIMETRY; EXPOSURE; OCCUPATIONAL; DIAGNOSTIC RADIOLOGY; DOSE ASSESSMENT;
D O I
10.1097/00004032-199508000-00011
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
Radiation doses to staff involved with pediatric cardiac catheterization were measured using thcrmoiuminescent dosimeters in 18 procedures. The average doses to the lens and thyroid, and the effective dose per procedure to the main operating physicians was 88, 180, and 8 mu Sv, respectively; to assistant physicians, 23, 51, and 2 mu Sv; and to technicians, 23, 27, and 2 mu Sv. In some procedures, the dose to the technician's hand approached 1,500 mu Sv. The doses received by physicians mere proportional to cineangiographic time but with no correlation with integrated currents, The number of procedures which may be performed in a year by individual staff members was estimated to be 430 and 2,780 procedures for physicians and assistants, respectively, It was suggested that the front of the neck is an adequate position for the dosimeter to measure doses during pediatric catheterization.
引用
收藏
页码:261 / 264
页数:4
相关论文
共 15 条
[1]
RADIATION EXPOSURE TO PERSONNEL DURING CARDIAC CATHETERIZATION [J].
ARDRAN, GM ;
FURSDON, PS .
RADIOLOGY, 1973, 106 (03) :517-518
[2]
RADIATION EXPOSURE TO OPERATOR PERFORMING CARDIAC ANGIOGRAPHY WITH U-ARM SYSTEMS [J].
BALTER, S ;
SONES, FM ;
BRANCATO, R .
CIRCULATION, 1978, 58 (05) :925-932
[3]
OCCUPATIONAL EXPOSURE IN X-RAY-DIAGNOSIS [J].
DREXLER, G ;
PANZER, W .
RADIATION PROTECTION DOSIMETRY, 1990, 32 (03) :163-170
[4]
THE RELATIONSHIP OF EFFECTIVE DOSE TO PERSONNEL AND MONITOR READING FOR SIMULATED FLUOROSCOPIC IRRADIATION CONDITIONS [J].
FAULKNER, K ;
MARSHALL, NW .
HEALTH PHYSICS, 1993, 64 (05) :502-508
[5]
EFFECT OF PULSED PROGRESSIVE FLUOROSCOPY ON REDUCTION OF RADIATION-DOSE IN THE CARDIAC-CATHETERIZATION LABORATORY [J].
HOLMES, DR ;
WONDROW, MA ;
GRAY, JE ;
VETTER, RJ ;
FELLOWS, JL ;
JULSRUD, PR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (01) :159-162
[6]
ICRP, 1991, COMP DOS COEFF BAS I, V21
[7]
AN INVESTIGATION OF THE RADIATION-DOSE TO STAFF DURING CARDIAC RADIOLOGICAL STUDIES [J].
JEANS, SP ;
FAULKNER, K ;
LOVE, HG ;
BARDSLEY, RA .
BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (689) :419-428
[8]
SOME CHARACTERISTICS OF MG2SIO4 (TB) PHOSPHOR FOR MEASURING DOSES FROM DIAGNOSTIC X-RAYS [J].
LI, LB ;
KAI, M ;
KUSAMA, T .
RADIATION PROTECTION DOSIMETRY, 1995, 59 (02) :149-152
[9]
RADIATION EXPOSURE TO PERSONNEL DURING CARDIAC CATHETERIZATION - PRELIMINARY STUDY [J].
MALSKY, SJ ;
ROSWIT, B ;
REID, CB ;
HAFT, J .
RADIOLOGY, 1971, 100 (03) :671-&
[10]
RADIATION EXPOSURE AND PROTECTION IN CARDIAC-CATHETERIZATION LABORATORIES [J].
MILLER, SW ;
CASTRONOVO, FP .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (01) :171-176