AN IMPLANTABLE SEAL-LESS CENTRIFUGAL PUMP WITH INTEGRATED DOUBLE-DISK MOTOR

被引:18
作者
SCHIMA, H [1 ]
SCHMALLEGGER, H [1 ]
HUBER, L [1 ]
BIRGMANN, I [1 ]
REINDL, C [1 ]
SCHMIDT, C [1 ]
ROSCHAL, K [1 ]
WIESELTHALER, G [1 ]
TRUBEL, W [1 ]
LOSERT, U [1 ]
WOLNER, E [1 ]
机构
[1] UNIV VIENNA,DEPT CARDIOTHORAC SURG & LBI CARDIAC SURG,A-1090 VIENNA,AUSTRIA
关键词
CENTRIFUGAL PUMP; SEAL-LESS; AXLE-LESS; MAGNETIC BEARING; MINIATURIZED DRIVER;
D O I
10.1111/j.1525-1594.1995.tb02395.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Thrombus formation and sealing problems at the shaft as well as the compact and efficient design of the driving unit have been major difficulties in the construction of a long-term implantable centrifugal pump. To eliminate the problems of the seal, motor size, and efficiency, two major steps were taken by modifying the Vienna implantable centrifugal pump. First, a special driving unit was developed, in which the permanent magnets of the motor themselves are used for coupling the force into the rotor. Second, the rotor shaft in the pumping chamber was eliminated by adopting a concept recently presented by Ohara, The rotor is supported by 3 pins, which run on a carbon disk, whose concave shape leads to stabilization. The device has the following specifications: size: 65 mm (diameter) by 35 mm (height), 101 cm(3); priming volume 30 cm(3), 240 g; and a 6-pole brushless double disk DC motor. The required input power of the described prototype is 15 W at 150 mm Hg, 5 L/min (overall eta = 11%), and has an in vitro index of hemolysis (IH) of 0.0046 g/100 L. The test for in vitro thrombus growth exhibited far less thrombus formation in the new design than in designs with axles. In conclusion, the design of a special driving unit and the elimination of the axle led to the construction of a small pump with very low blood traumatization.
引用
收藏
页码:639 / 643
页数:5
相关论文
共 14 条
[1]   RECENT STUDIES OF THE CENTRIFUGAL BLOOD PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER [J].
AKAMATSU, T ;
TSUKIYA, T ;
NISHIMURA, K ;
PARK, CH ;
NAKAZEKI, T .
ARTIFICIAL ORGANS, 1995, 19 (07) :631-634
[2]   A FLOW VISUALIZATION STUDY OF THE NCVC CENTRIFUGAL BLOOD PUMP [J].
ARAKI, K ;
TAENAKA, Y ;
MASUZAWA, T ;
TATSUMI, E ;
WAKISAKA, Y ;
WATARI, M ;
NAKATANI, T ;
AKAGI, H ;
BABA, Y ;
ANAI, H ;
PARK, YH ;
EYA, K ;
TODA, K ;
TAKANO, H .
ARTIFICIAL ORGANS, 1994, 18 (09) :669-672
[3]   MOTOR DESIGN WITH LARGE AIR GAP FOR CENTRIFUGAL BLOOD PUMPS USING RARE-EARTH MAGNETS [J].
BINDER, A ;
SCHIMA, H ;
SCHMALLEGGER, H .
ARCHIV FUR ELEKTROTECHNIK, 1990, 73 (04) :261-269
[4]  
BUTLER KC, 1991, P INT WORKSHOP ROTAR, P148
[5]  
HUBER L, 1993, BIOMED TECH, V38, P269
[6]  
JARVIK R, 1992, ARTIF ORGANS, V19, P565
[7]   DEVELOPMENT OF AN AXIAL-FLOW VENTRICULAR ASSIST DEVICE - IN-VITRO AND IN-VIVO EVALUATION [J].
MIZUGUCHI, K ;
DAMM, G ;
BENKOWSKY, R ;
ABER, G ;
BACAK, J ;
SVJKOVSKY, P ;
GLUECK, J ;
TAKATANI, S ;
NOSE, Y ;
NOON, GP ;
DEBAKEY, ME .
ARTIFICIAL ORGANS, 1995, 19 (07) :653-659
[8]   IN-VITRO ANALYSIS OF THE FLOATING MODE PHENOMENON IN THE FREE IMPELLER GYRO PUMP [J].
OHARA, Y ;
TAKATANI, S ;
NOSE, Y .
ARTIFICIAL ORGANS, 1995, 19 (07) :635-638
[9]  
Olsen D B, 1985, Trans Am Soc Artif Intern Organs, V31, P395
[10]  
SCHIMA H, 1993, ARTIF ORGANS, V17, P605