ULTRASENSITIVE NEAR-IR FLUORESCENCE DETECTION FOR CAPILLARY GEL-ELECTROPHORESIS AND DNA-SEQUENCING APPLICATIONS

被引:65
作者
WILLIAMS, DC [1 ]
SOPER, SA [1 ]
机构
[1] LOUISIANA STATE UNIV,DEPT CHEM,BATON ROUGE,LA 70803
关键词
D O I
10.1021/ac00115a010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electropherograms of oligonucleotides labeled with near-IR fluorescent dyes, separated by capillary gel electrophoresis and detected using an ultrasensitive near-IR fluorescence detection system, are presented. A universal M13 sequencing primer was labeled on the 5' end with a near-IR dye containing an isothiocyanate functional group. Comparison of the on-column detection limits in capillary gel electrophoresis for the near-IR dye-labeled sequencing primer to those obtained for a visible fluorescein-labeled primer indicated improved sensitivity for the near-IR case. The detection limit was found to be 3.4 x 10(-20) mol (SNR = 3) for the near-IR dye-labeled primer, while the on-column detection limit for the fluorescein analog was 1.5 x 10(-18) mol (SNR = 3). The sequence of nucleotide bases in an M13mp18 template was determined using a single lane, single dye technique. The molar concentrations of the ddNTPs used during chain extension reactions were varied to achieve a ratio of 4:2:1:0 (A:C:G:T), which allowed the identification of each terminal base via fluorescence intensity measurements. Sequencing ladders were prepared from the M13mp18 template using standard Sanger dideoxy chain-terminating techniques, the modified T7 DNA polymerase, and the near-IR dye-labeled M13 universal primer. The data indicated reliable sequence determination by the 4:2:1:0 (A:C:G:T) peak height identification method up to 250 bases from the annealing site. Comparison of the known sequence of the M13mp18 plasmid to that obtained using this protocol yielded a base-calling accuracy of 84% for the 4:2:1:0 ratio.
引用
收藏
页码:3427 / 3432
页数:6
相关论文
共 39 条
[1]  
ANDREWSWILBERFO.D, 1990, SPECTROCHIM ACTA A, V46, P1153
[2]   ONE LABEL, ONE TUBE, SANGER DNA SEQUENCING IN ONE AND 2 LANES ON A GEL [J].
ANSORGE, W ;
ZIMMERMANN, J ;
SCHWAGER, C ;
STEGEMANN, J ;
ERFLE, H ;
VOSS, H .
NUCLEIC ACIDS RESEARCH, 1990, 18 (11) :3419-3420
[3]   EVALUATION OF NEAR-INFRARED DYES AS LABELS FOR IMMUNOASSAYS UTILIZING LASER DIODE DETECTION - DEVELOPMENT OF NEAR-INFRARED DYE IMMUNOASSAY (NIRDIA) [J].
BOYER, AE ;
LIPOWSKA, M ;
ZEN, JM ;
PATONAY, G ;
TSANG, VCW .
ANALYTICAL LETTERS, 1992, 25 (03) :415-428
[4]   DNA-SEQUENCING BY CAPILLARY ELECTROPHORESIS - USE OF A 2-LASER 2-WINDOW INTENSIFIED DIODE-ARRAY DETECTION SYSTEM [J].
CARSON, S ;
COHEN, AS ;
BELENKII, A ;
RUIZMARTINEZ, MC ;
BERKA, J ;
KARGER, BL .
ANALYTICAL CHEMISTRY, 1993, 65 (22) :3219-3226
[5]   LOW-COST, HIGH-SENSITIVITY LASER-INDUCED FLUORESCENCE DETECTION FOR DNA SEQUENCING BY CAPILLARY GEL-ELECTROPHORESIS [J].
CHEN, DY ;
SWERDLOW, HP ;
HARKE, HR ;
ZHANG, JZ ;
DOVICHI, NJ .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :237-246
[6]   2-LABEL PEAK-HEIGHT ENCODED DNA SEQUENCING BY CAPILLARY GEL-ELECTROPHORESIS - 3 EXAMPLES [J].
CHEN, DY ;
HARKE, HR ;
DOVICHI, NJ .
NUCLEIC ACIDS RESEARCH, 1992, 20 (18) :4873-4880
[7]  
CHEN DY, 1991, P SOC PHOTO-OPT INS, V1435, P161, DOI 10.1117/12.44240
[8]   SEMICONDUCTOR LASER-INDUCED FLUORESCENCE DETECTION IN CAPILLARY ELECTROPHORESIS USING A CYANINE DYE [J].
CHEN, FTA ;
TUSAK, A ;
PENTONEY, S ;
KONRAD, K ;
LEW, C ;
KOH, E ;
STERNBERG, J .
JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (02) :355-360
[9]   HIGH-SPEED SEPARATIONS OF DNA SEQUENCING REACTIONS BY CAPILLARY ELECTROPHORESIS [J].
DROSSMAN, H ;
LUCKEY, JA ;
KOSTICHKA, AJ ;
DCUNHA, J ;
SMITH, LM .
ANALYTICAL CHEMISTRY, 1990, 62 (09) :900-903
[10]   BINARY SOLVENT EFFECTS IN CAPILLARY ZONE ELECTROPHORESIS WITH ULTRASENSITIVE NEAR-IR FLUORESCENCE DETECTION OF RELATED TRICARBOCYANINE DYES AND DYE-LABELED AMINO-ACIDS [J].
FLANAGAN, JH ;
LEGENDRE, BL ;
HAMMER, RP ;
SOPER, SA .
ANALYTICAL CHEMISTRY, 1995, 67 (02) :341-347