FREE-HAND ULTRASOUND-GUIDED RENAL BIOPSY - REPORT OF 650 CONSECUTIVE CASES

被引:35
作者
MEOLA, M
BARSOTTI, G
CUPISTI, A
BUONCRISTIANI, E
GIOVANNETTI, S
机构
[1] Istituto Clinica Medica I, Universita di Pisa, I-56100 Pisa
来源
NEPHRON | 1994年 / 67卷 / 04期
关键词
RENAL BIOPSY; KIDNEY ULTRASOUND; INTERVENTIONAL SONOGRAPHY;
D O I
10.1159/000188016
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
In the past 4 years we have carried out 650 percutaneous renal biopsies (PRB), 54 on transplanted and 596 on native kidneys. PRB was performed with a 14-gauge one-piece disposable needle that was introduced free-handedly into the lumbar wall without any form of fixed guidance or support. Ultrasound was used to locate the kidney pole and to follow the progression of the needle tip in the renal parenchyma. The time needed for the whale procedure was about 5 min. The tissue specimen was adequate for histological evaluation in 98.8% of the cases. The prevalence of post-biospy complications (haematuria, pain, anaemia) was 2.5%. Haematuria was not a common complication (1.6%) in our series, whereas clinically silent perirenal haematoma was common. Mild perirenal bleeding (volume <5 ml) was found in 40 of a series of 150 patients (26.6%) who underwent ultrasound scan 24 h after the PRB. Haematoma exceeding 100 ml was revealed with US in only 0.6% of the patients. We conclude that free-hand ultrasound-guided PRB makes this technique easier, highly successful, timesaving and almost free of severe side effects.
引用
收藏
页码:425 / 430
页数:6
相关论文
共 22 条
[21]   THE BIOPTY CUT PROCEDURE FOR RENAL BIOPSIES [J].
WORTH, DP ;
KHANNA, SK ;
UBHI, CS ;
IRVING, HC .
BRITISH MEDICAL JOURNAL, 1988, 296 (6636) :1603-1603
[22]  
YASHIMOTO M, 1988, CLIN NEPHROL, V30, P106