SUPERPARAMAGNETIC IRON-OXIDE - DETECTION OF FOCAL LIVER-LESIONS AT HIGH-FIELD-STRENGTH MR-IMAGING

被引:56
作者
DUDA, SH [1 ]
LANIADO, M [1 ]
KOPP, AF [1 ]
GRONEWALLER, E [1 ]
AICHER, KP [1 ]
PAVONE, P [1 ]
JEHLE, E [1 ]
CLAUSSEN, CD [1 ]
机构
[1] UNIV ROMA LA SAPIENZA, DEPT RADIOL, I-00185 ROME, ITALY
关键词
CONTRAST ENHANCEMENT; CONTRAST MEDIA; EFFECTS; IRON; LIVER; LIVER NEOPLASMS; DIAGNOSIS;
D O I
10.1002/jmri.1880040314
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AMI-25 was evaluated at 1.5 T as a superparamagnetic iron oxide contrast agent for the liver. Sixteen patients with up to five suspected focal liver lesions were examined with T1-, proton-density-, and T2-weighted spin-echo sequences before and after intravenous administration of AMI-25 (15 mumol/kg iron). The contrast-to-noise ratio (C/N) increased from 1.8 to 3.5 on 600/15 (TR msec/TE msec) images and from 1.7 to 7.9 on 2,500/15 images after AMI-25 administration (P < .01). C/N did not change significantly on 2.500/90 images. Two blinded readers counted the number of lesions visible on unenhanced and contrast-enhanced images, with the 32 sets of images of the 16 patients presented in random order. Both readers identified more lesions on AMI-25-enhanced images, but the difference was not statistically significant (P > .05). Two patients reported minor side effects (flushing, sensation of heat, lower back pain). On the basis of the results obtained in a limited number of patients, the authors conclude that at 1.5 T. AMI-25 does not significantly improve the detection of focal liver lesions on conventional spin-echo images.
引用
收藏
页码:309 / 314
页数:6
相关论文
共 24 条
  • [11] HILLMAN RS, 1990, PHARMACOL BASIS THER, P1277
  • [12] DETECTION OF LIVER METASTASES WITH SUPERPARAMAGNETIC IRON-OXIDE IN 15 PATIENTS - RESULTS OF MR IMAGING AT 1.5-T
    MARCHAL, G
    VANHECKE, P
    DEMAEREL, P
    DECROP, E
    KENNIS, C
    BAERT, AL
    VANDERSCHUEREN, E
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (04) : 771 - 775
  • [13] DYNAMIC GADOLINIUM-ENHANCED RAPID ACQUISITION SPIN-ECHO MR IMAGING OF THE LIVER
    MIROWITZ, SA
    LEE, JKT
    GUTIERREZ, E
    BROWN, JJ
    HEIKEN, JP
    EILENBERG, SS
    [J]. RADIOLOGY, 1991, 179 (02) : 371 - 376
  • [14] MUDGE GH, 1990, PHARMACOL BASIS THER, P682
  • [15] INTRAARTERIAL PORTOGRAPHY WITH GADOPENTETATE DIMEGLUMINE - IMPROVED LIVER-TO-LESION CONTRAST IN MR-IMAGING
    PAVONE, P
    GIULIANI, S
    CARDONE, G
    OCCHIATO, R
    DIRENZI, P
    PETRONI, GA
    BUONI, C
    PASSARIELLO, R
    [J]. RADIOLOGY, 1991, 179 (03) : 693 - 697
  • [16] DYNAMIC SIGNAL INTENSITY CHANGES IN LIVER WITH SUPERPARAMAGNETIC MR CONTRAST AGENTS
    REIMER, P
    KWONG, KK
    WEISSKOFF, R
    COHEN, MS
    BRADY, TJ
    WEISSLEDER, R
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (02): : 177 - 181
  • [17] FERRITE PARTICLES - A SUPERPARAMAGNETIC MR CONTRAST AGENT FOR ENHANCED DETECTION OF LIVER-CARCINOMA
    SAINI, S
    STARK, DD
    HAHN, PF
    BOUSQUET, JC
    INTROCASSO, J
    WITTENBERG, J
    BRADY, TJ
    FERRUCCI, JT
    [J]. RADIOLOGY, 1987, 162 (01) : 217 - 222
  • [18] FERRITE PARTICLES - A SUPERPARAMAGNETIC MR CONTRAST AGENT FOR THE RETICULOENDOTHELIAL SYSTEM
    SAINI, S
    STARK, DD
    HAHN, PF
    WITTENBERG, J
    BRADY, TJ
    FERRUCCI, JT
    [J]. RADIOLOGY, 1987, 162 (01) : 211 - 216
  • [19] SEIFEN E, 1992, ALLGEMEINE SPEZIELLE, P404
  • [20] SUPERPARAMAGNETIC IRON-OXIDE - CLINICAL-APPLICATION AS A CONTRAST AGENT FOR MR IMAGING OF THE LIVER
    STARK, DD
    WEISSLEDER, R
    ELIZONDO, G
    HAHN, PF
    SAINI, S
    TODD, LE
    WITTENBERG, J
    FERRUCCI, JT
    [J]. RADIOLOGY, 1988, 168 (02) : 297 - 301