DEVELOPMENT OF AN ETHANOL-SELECTIVE OPTODE MEMBRANE BASED ON A REVERSIBLE CHEMICAL RECOGNITION PROCESS

被引:63
作者
SEILER, K [1 ]
WANG, KM [1 ]
KURATLI, M [1 ]
SIMON, W [1 ]
机构
[1] SWISS FED INST TECHNOL,DEPT ORGAN CHEM,UNIV STR 16,CH-8092 ZURICH,SWITZERLAND
关键词
ETHANOL-SELECTIVE OPTODE MEMBRANE;
D O I
10.1016/S0003-2670(00)82491-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lipophilic trifluoroacetophenone derivatives incorporated in plasticized PVC membranes are able to selectively extract water and alcohols from the sample solution into the organic membrane phase, reversibly forming hydrates and hemi-acetals, respectively. Since this is accompanied by a change in the absorption spectrum of the acetophenone isologue, the chemical recognition process can directly be translated into an optical signal. With N-acetyl-N-dodecyl-4-trifluoroacetylaniline (ETH 6022) as the electrically neutral, lipophilized carrier ethanol can be determined from 0.5 to 35% (v/v) in aqueous solutions. The calibration curve for different ethanol-water mixtures shows a good correlation with the mathematically derived formalism and thus confirms the theoretically expected behavior. Besides high reproducibility of the optical signals, very short response times of less than 30 s were realized. The optode membrane presented exhibits a preference for ethanol compared to water by a factor greater than 11. The selectivities for several primary alcohols, such as methanol, ethanol, 1-propanol and 1-n-butanol, are comparable, but isopropanol and tert.-butanol are rejected by a factor of about 10. The alcohol concentration in different beverages was determined to evaluate the reliability of the system. The values obtained for wine, beer and different spirits show an excellent correlation with those obtained by a conventional approach involving distillation and density measurements. A residual standard deviation of +/- 0.27% (v/v) over the 0.7-40% (v/v) range was found.
引用
收藏
页码:151 / 160
页数:10
相关论文
共 37 条
  • [11] THEORY AND APPLICATIONS OF ION-SELECTIVE ELECTRODES .8.
    KORYTA, J
    [J]. ANALYTICA CHIMICA ACTA, 1990, 233 (01) : 1 - 30
  • [12] SPECTROPHOTOMETRIC DETERMINATION OF ETHANOL IN BLOOD USING A FLOW-INJECTION SYSTEM WITH AN IMMOBILIZED ENZYME (ALCOHOL-DEHYDROGENASE) REACTOR COUPLED TO AN ONLINE DIALYZER
    MAEDER, G
    VEUTHEY, JL
    PELLETIER, M
    HAERDI, W
    [J]. ANALYTICA CHIMICA ACTA, 1990, 231 (01) : 115 - 119
  • [13] OPTICAL CHEMICAL SENSOR BASED ON SURFACE-PLASMON MEASUREMENT
    MATSUBARA, K
    KAWATA, S
    MINAMI, S
    [J]. APPLIED OPTICS, 1988, 27 (06): : 1160 - 1163
  • [14] ROLE OF TRIFLUOROACETOPHENONE SOLVENTS AND QUATERNARY AMMONIUM-SALTS IN CARBONATE-SELECTIVE LIQUID MEMBRANE ELECTRODES
    MEYERHOFF, ME
    PRETSCH, E
    WELTI, DH
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (01) : 144 - 150
  • [15] CARRIERS FOR CHEMICAL SENSORS - DESIGN-FEATURES OF OPTICAL SENSORS (OPTODES) BASED ON SELECTIVE CHROMOIONOPHORES
    MORF, WE
    SEILER, K
    LEHMANN, B
    BEHRINGER, C
    HARTMAN, K
    SIMON, W
    [J]. PURE AND APPLIED CHEMISTRY, 1989, 61 (09) : 1613 - 1618
  • [16] OZAWA S, IN PRESS ANAL CHEM
  • [17] PERRIN DD, 1983, BUFFERS PH METAL ION
  • [18] OPTICAL AND FIBRE-OPTIC SENSORS FOR VAPORS OF POLAR-SOLVENTS
    POSCH, HE
    WOLFBEIS, OS
    PUSTERHOFER, J
    [J]. TALANTA, 1988, 35 (02) : 89 - 94
  • [19] POSTEL W, 1984, FLAVOUR RES ALCHOLIC, V3, P175
  • [20] DETERMINATION OF ETHANOL IN HUMAN FLUIDS .2. DETERMINATION OF ETANOL IN URINE, BREATH AND SALIVA
    RUZ, J
    FERNANDEZ, A
    DECASTRO, MDL
    VALCARCEL, M
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1986, 4 (05) : 559 - 564