LC/ESI-MS DETERMINATION OF PROTEINS USING CONVENTIONAL LIQUID-CHROMATOGRAPHY AND ULTRASONICALLY ASSISTED ELECTROSPRAY

被引:36
作者
BANKS, JF
QUINN, JP
WHITEHOUSE, CM
机构
[1] Analytica of Branford, Inc., Branford, Connecticut 06405
关键词
D O I
10.1021/ac00093a024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Conventional unassisted electrospray ionization mass spectrometry (ESI-MS) has severe limitations as a liquid chromatography (LC) interface due to the few solvent compositions which can be electrosprayed without some type of assistance. LC mobile phases which have high flow rates (over 5 mu L/min), high conductivity, or high surface tension are normally unsuitable for use with ESI. For this reason, an ultrasonic nebulizer has been developed which mechanically creates the fine spray of droplets needed for ESI and thus functions independently of the solvent composition. This device also operates at considerably higher liquid flow rates, up to several hundred microliters per minute. To characterize the system's performance, the ultrasonic nebulizer frequency, source electrode potentials, and drying and focusing gas flow rates were studied and optimized. Also, droplet size measurements were taken using a phase-Doppler anemometer, which showed consistent nebulizer performance up to a liquid flow rate of several hundred microliters per minute. Finally, the ultrasonic nebulizer was used for an LC application involving the separation of proteins on 1.0 and 2.1 mm i.d. columns. LC flow rates of up to 200 mu L/min of mobile phases containing 0.1% trifluoroacetic acid could be easily nebulized. With the 1.0 mm i.d. column, as little as 32 fmol of cytochrome c could be detected in selected ion monitoring mode.
引用
收藏
页码:3688 / 3695
页数:8
相关论文
共 30 条
  • [1] ULTRASONICALLY ASSISTED ELECTROSPRAY-IONIZATION FOR LC/MS DETERMINATION OF NUCLEOSIDES FROM A TRANSFER-RNA DIGEST
    BANKS, JF
    SHEN, S
    WHITEHOUSE, CM
    FENN, JB
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (03) : 406 - 414
  • [2] BANKS JF, 1993, PITTSBURGH C ATLANTA
  • [3] TIME-OF-FLIGHT MASS-SPECTROMETRY WITH AN ELECTROSPRAY ION-BEAM
    BOYLE, JG
    WHITEHOUSE, CM
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (18) : 2084 - 2089
  • [4] DETERMINATION OF SULFONATED AZO DYES BY LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY
    BRUINS, AP
    WEIDOLF, LOG
    HENION, JD
    BUDDE, WL
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (22) : 2647 - 2652
  • [5] ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY
    BRUINS, AP
    COVEY, TR
    HENION, JD
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (22) : 2642 - 2646
  • [6] ELECTROSPRAY IONIZATION MAGNETIC-SECTOR MASS-SPECTROMETRY - CALIBRATION, RESOLUTION, AND ACCURATE MASS MEASUREMENTS
    CODY, RB
    TAMURA, J
    MUSSELMAN, BD
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (14) : 1561 - 1570
  • [7] DESIGN AND PERFORMANCE OF AN ELECTROSPRAY IONIZATION SOURCE FOR A DOUBLY-FOCUSING MAGNETIC-SECTOR MASS-SPECTROMETER
    GALLAGHER, RT
    CHAPMAN, JR
    MANN, M
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (10) : 369 - 372
  • [8] HIGH-RESOLUTION ELECTROSPRAY MASS-SPECTRA OF LARGE MOLECULES
    HENRY, KD
    QUINN, JP
    MCLAFFERTY, FW
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (14) : 5447 - 5449
  • [9] FOURIER-TRANSFORM MASS-SPECTROMETRY OF LARGE MOLECULES BY ELECTROSPRAY IONIZATION
    HENRY, KD
    WILLIAMS, ER
    WANG, BH
    MCLAFFERTY, FW
    SHABANOWITZ, J
    HUNT, DF
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1989, 86 (23) : 9075 - 9078
  • [10] Characterization of peptides bound to the class I MHC molecule HLA-A2.1 by mass spectrometry (Reprinted from Science, vol 255, March 6, 1992)
    Hunt, Donald F.
    Henderson, Robert A.
    Shabanowitz, Jeffrey
    Sakaguchi, Kazuyasu
    Michel, Hanspeter
    Sevilir, Noelle
    Cox, Andrea L.
    Appella, Ettore
    Engelhard, Victor H.
    [J]. JOURNAL OF IMMUNOLOGY, 2007, 179 (05) : 2669 - 2671